Programming Features Eg-1400 And Eg-1600 - Omega Research & Development Excalibur Gold ATV Series Comprehensive Installer Technical Manual

Supplement
Table of Contents

Advertisement

Step 2b - If the system has had the Selectable Override Code custom-programmed, once stage #1 been properly entered (which can be up to nine Valet
Switch presses) the system will acknowledge the entry by sounding the siren (or horn) for a short period, then one chirp (or a short honk). You now have
8.5 seconds to initiate stage #2 of entering the Override Code. Momentarily press the Valet Switch equal to the Override Code number programmed
for stage #2. The system will acknowledge the entry by sounding the siren for a short burst and two chirps (or the horn will sound one long, then two
short honks).
Step 3 - You now have 15 seconds access the desired Feature. This done by pressing the Valet Switch the number of times that are equal to Feature number
listed. For example, to change the Arming Delay to 45 seconds, press the Valet Switch twice as this is the second Feature on the list. The system will
acknowledge the Valet Switch entry by chirping the siren (or honking the horn) a number of times equal to the number of Valet Switch presses.
Step 4 - You have 15 seconds to change the chosen Feature. Press the transmitter's large upper button to turn the Feature ON, or press the small center button
to turn the Feature OFF. Turning the Feature ON is indicated by one siren chirp (or horn honk); turning the Feature OFF is indicated by two siren chirps
(or horn honks). If 15 seconds of no programming activity expires (not pressing either transmitter button or selecting another Feature) will cause the
system to exit the Features Programming Mode, which is indicated by two long siren chirps (or two long horn honks).
The 25 Programmable Features and their factory-set default settings are listed below. Following this each Programmable Feature and coding operation
is explained.
1)
Personal Coded Override: Default 1 & 0.
2)
Last Door Arming: Default OFF.
3)
Automatic Rearming: Default OFF.
4)
Starter Interrupt 90 Seconds After Ignition "Off" Or Disarming: Default OFF.
5)
Doors Lock Upon Last Door Arming: Default OFF.
6)
Doors Lock Upon Automatic Rearming: Default OFF.
7)
Doors Lock Upon Ignition "On": Default ON.
8)
Unlock #1 Upon Ignition "Off": Default ON.
9)
Unlock #2 Upon Ignition "Off": Default ON.
10)
Open Door Bypass For The Previous Three Features: Default ON.
11)
Confirmation Horn Honks (or Siren Chirps): Default ON.
12)
Confirmation Horn Honks (or Siren Chirps) While In Valet Mode: Default OFF.
13)
30 Or 60 Second Activated Alarm Cycle: Default 60 Seconds.
14)
Lights On 30 Or 5 Seconds Upon Disarm: Default 30 Seconds.
15)
Disarm System Upon Trunk Release: Default ON.
16)
Doorlock Pulse Time .8 Or 3 Seconds: Default .8 second.
17)
Double Pulse Unlock (DPU
TM
): Default OFF.
Page 34