Trunk Release Output
The function of the Gray wire is to provide an optional output, the primary use being trunk release. For model EG-1200
press and hold the transmitter's small center button for three seconds to activate this output. When activated the Gray wire will provide a 250ma ground pulse
for 1 second; or, stay grounded for as long as you depress the transmitter button(s), for up to 15 seconds. Also, the security system can be programmed to
automatically disarm, chirp the siren twice, unlock the doors and turn the lights on for 30 seconds. The remote trunk release feature can be operated anytime
with the ignition switch is "off", or it may also be operated while ignition switch is "on", provided that a door is open at the same time the transmitter's small
center button is pressed. This prevents the trunk or rear hatch from being opened from the transmitter while driving. Whenever this output is used, the siren
will chirp twice.
Unless the vehicle's trunk
release switch negatively
triggers a release relay
which draws no more than
250ma, an optional relay
must be used. Connect the
Gray wire to relay pin (86),
and connect constant 12 volt
positive to relay pin (85).
Connect pins 87, 87a & 30
as indicated in this typical
diagram:
Wiring Connections - 8 Wire Connector
3rd Channel Output
The function of the Pink wire is to provide an optional output similar to the Gray trunk release wire. Pressing the proper transmitter button for three seconds
activates this output. Once activated, this output will last for one second, or, for as long as transmitter button is held down, with a maximum of 15 seconds.
This function can be used to activate other optional modules (Example: car starting equipment or power window roll up units). For most applications an optional
relay will be needed (use the diagram on the following page or the above diagram for the Gray wire). This output will not disarm the security system when
activated. For the EG-1200
ATV
, EG-1400
Security
System
Control
Module
To 12 Volt
Release
Switch
Wiring An Optional Relay For Trunk Release.
ATV
and EG-1600
ATV
, the small lower transmitter button is used to activate this output.
To Positive Or Negative As Needed. In This Case,
Negative Is Required. In Others, Positive. In Some
Applications The Wire Will Rest At Ground. Cut
The Wire, Switch Side To Pin 87a, Solenoid Side
To Pin 30.
Gray Wire
86
87
87a
Relay
Positive
30
85
Page 13
Gray Wire
ATV
, EG-1400
ATV
and EG-1600
To 12 Volt
Positive
Release
Solenoid
Pink Wire
Gray Trunk Release Output Wire