Error Codes - Kemppi MasterTig 235ACDC GM Operating Manual

Hide thumbs Also See for MasterTig 235ACDC GM:
Table of Contents

Advertisement

Tip: For checking the correct welding settings, you can also use Weld Assist.
Varying welding performance
Check that the welding torch is physically intact and the nozzle is clear of any obstructions.
Check that the welding torch is not overheating.
Check that the earth return clamp is properly attached to a clean surface of the workpiece.

5.1 Error codes

Error
Error descrip-
Possible reason
code
tion
1
Power source
Power source calibration has been lost.
not calibrated
Voltage in mains network is too low.
2
Too low
mains voltage
3
Too high
Voltage in mains network is too high.
mains voltage
4
Power source
Too long welding session with high power.
is overheated
17
Phase is miss-
One or more phases are missing from the
ing from
mains supply.
mains supply
20
Power source
Cooling capacity is reduced in the power
cooling fail-
source.
ure
24
Cooling liquid
Too long welding session with high power or
overheated
high ambient temperature.
26
Cooling liquid
No cooling liquid or circulation is blocked.
not cir-
culating
27
Cooler not
Cooling is turned on in the settings menu, but
found
cooler is not connected to power source or
cabling is faulty.
34
Unknown
An unknown load connected to DIX con-
nectors.
welding load
35
Too high
Current drawn from the mains is too high.
mains current
36
DC-link under-
DC-link voltage is too low.
voltage
37
DC-link over-
DC-link voltage is too high.
voltage
38
Mains voltage
Mains voltage is too high or too low.
too high or
too low
© Kemppi
MasterTig 235ACDC, 325DC, 335ACDC
Proposed action
Restart the power source. If problem persists, contact
Kemppi service. Note: The equipment operation is limited
when this error occurs.
Restart the power source. If problem persists, contact
Kemppi service.
Restart the power source. If problem persists, contact
Kemppi service.
Do not shut down, let the fans cool the machine. If fans are
not running, contact Kemppi service.
Check the mains cable and its connectors. Check the
voltage of mains supply.
Clean the filters and clear any dirt from the cooling channel.
Check that the cooling fans are running. If not, contact
Kemppi service.
Do not turn off the cooler. Let the liquid circulate until the
fans cool it down. If fans are not running, contact Kemppi
service.
Check the liquid level in the cooler. Check hoses and con-
nectors for blockage.
Check the cooler connections. Ensure that the cooling is
turned off in the settings menu, if the cooler is not in use.
Remove any unintended resistive load connected to the
welding equipment and restart the power source.
Reduce welding power.
Check the mains voltage and/or the supply cable.
Check the mains voltage.
Check the mains voltage and/or the supply cable.
57/77
Operating manual - EN
1920900 / 1939

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mastertig 325dc gMastertig 325dcMastertig 325dc gmMastertig 335acdcMastertig 335acdc gmMastertig 335acdc g ... Show all

Table of Contents