Change of the reference for the configuration of the input module between
local and field bus
After the commissioning of an input module is finished, its configuration can be stored in the
machine control (e.g. PLC). With each restart, the input module can download this configuration
via the field bus. In this way, it is guaranteed, that the machine control and the input module work
with the same information, even if the input module was exchanged. The exact proceeding for this
procedure depends on the used field bus and therefore has to be looked up in the relevant
documentation.
If this downloading of the configuration via the field bus should be prevented, a change to local
configuration can be done as described in the following.
Operator
options
/\ or \/
ESC
OK
/\ or \/
ESC
OK
/\ or \/
ESC
OK
/\ or \/
ESC
OK
Description
Change to another mode except RUN
Change to RUN mode
Change to system settings
Change to other systen setting in the SET-mode
Change to SET-MAIN menue
Change to selection of local / field bus
Change between local / field bus
Leave edit mode
Confirmation of selected setting
Change to other systen setting in the SET-mode
Change to SET-MAIN menue
Change between local / field bus
Planning and Installation Guidelines
33