Planning and
Installation Guidelines
V 6
Technical Description

2.4 Flush mounting and non flush mounting

Fig. 2.3: Correct mounting of flush and non flush mountable sensor heads in metal materials

2.5 Mutual influence

D
correctly mounted non
flush mountable sensor
heads of the same type
Fig. 2.4: Correct mounting of sensor heads of the same type considering the minimum clearances
Wireless Proximity Switches / Issue: 09.2004
The product range of wireless proximity switches includes flush mountable as well as non
flush mountable sensor heads. Flush mountable sensor heads can be mounted in the
machine in a way that they are particularly well protected against mechanical damages.
Compared with that, the non flush mountable sensor heads have a significant higher
switching distance. However, their plastic cap has to stand out of the metal environment as
shown in the figure.
correctly mounted
flush mountable
sensor head
In order to avoid mutual influences, sensor heads of the same type have to be mounted as
shown in the figure, considering the minimum clearances.
3 x D
D
D
D
D
3 x D
correctly mounted
non flush mountable
sensor head
D
D
D
correctly mounted flush
mountable sensor heads
of the same type