Installing Battery Back Up - Overhead door INFINITY 2000 Installation, Programming, Operating Manual

Residential wall mount opener
Table of Contents

Advertisement

Installing the Battery Back-up (BBU)
AC power must be present to set limits. DO NOT attempt to set limits or any other programming steps
from battery power only.
1. Unplug power from opener.
2. Remove two screws securing bottom cover to opener head and remove cover.
3. Plug connector of battery backup into the BBU connection on bottom of opener. Ensure connector is inserted
in correct direction (SEE INSET).
4. Hold battery backup assembly at a 45 deg. angle to insert rear tabs into slots on bottom of opener.
5. Align battery backup to bottom of opener and secure with two screws removed in step 2.
MOUNTING
TABS
Testing The Battery Backup
NOTE: It is recommended that the battery backup be allowed to charge for 24 to 48 hours prior to testing. Initially, the
opener may not operate from the battery backup mode if battery is not fully charged.
Run the opener using the wall control or remote to ensure it is working properly.
1.
Turn off power to opener by unplugging from outlet or turning off breaker.
2.
Press wall control or remote control. Opener will run at a slower speed than normal.
3.
NOTE: See troubleshooting guide in this manual if any of the steps above fail.
After successful test, reconnect powerhead to power source.
4.
30
BATTERY BACKUP
MOUNTING SLOTS
TO PREVENT POSSIBLE
CAUTION
SERIOUS INJURY or DEATH
from electrocution AND REDUCE RISK of FIRE
— Disconnect ALL electric power sources and battery
power BEFORE performing ANY service or maintenance.
Install only in DRY locations - NOT INTENDED FOR OUTDOOR USE.
Use only 12V, 5AH, SLA replacment battery
(P/N 111658.0002.S).
POUR ÉVITER LES BLESSURES
ATTENTION
GRAVES VOIRE MORTELLE PAR
ÉLECTROCUATION POUR RÉDUIRE ES LES RISQUES
D'INCENDIE
—Débrancher toutes les sources d'alimentation électriques et
la pile avant d'e ectuer des opérations de réparation ou
d'entretien.
Installer uniquement dans des endroits secs—NE DOIT PAS ÊTRE
UTILISÉ À L'EXTÉRIEUR.
Utiliser uniquement une pile de remplacement de 12V, 5AH, SLA
(réf. 111658.0002.S).