Special Installation Information; Changing Force Settings - Overhead door INFINITY 2000 Installation, Programming, Operating Manual

Residential wall mount opener
Table of Contents

Advertisement

SPECIAL INSTALLATION INFORMATION

6
WARNING
!
TO AVOID INJURY OR DAMAGE
NEVER adjust the force settings to adjust for damage,
including an unbalanced door, binding door track or
broken spring.
Perform a CONTACT REVERSE TEST monthly.
CAUTION
!
DO NOT adjust force level above what is necessary to
allow for normal door operation.
IF FORCE SETTING IS ALTERED, ALL STEPS ON PAGE 20 MUST BE PERFORMED TO LOCK IN THE FORCE PROFILE
FOR PROPER DOOR OPERATION.
Force Settings:
Force settings are pre-programmed at the factory to force level 6 (See Chart Below) and applied during the Open/Closed Limit settings steps. For
normal use, these settings should not need adjustment.
Conditions possibly requiring adjustments are:
1. Doors with very stiff weather seals.
2. Doors that start down, STOP, and reverse before closing.
3. Doors that start up, but STOP before they completely open.
1. Press and hold both UP & DOWN arrow buttons until the ROUND LED turns RED. Release
buttons.
• LEDs will show current force level. SEE CHART.
Press either the UP or DOWN arrow button until the desired UP force setting is shown. SEE
2.
CHART.
Press & release the PRGM button to lock the desired UP FORCE setting.
3.
• Both LEDs will turn BLUE then go out confirming that the UP force setting has been
changed and is locked.
• LEDs will now show the current DOWN FORCE setting. SEE CHART.
4.
Press either the UP or DOWN arrow button until desired DOWN force setting is shown. SEE
CHART.
5.
Press & release the PRGM button to lock the desired DOWN FORCE setting.
• Both LEDs will turn BLUE then go out confirming that the DOWN force setting has been
changed and is locked.
6.
Perform all steps on page 20 to test operator.

CHANGING FORCE SETTINGS

IMPORTANT NOTICE
!
FORCE SETTING CHART
Force Level
Long LED
1 (LOWEST)
OFF
2
BLUE
3
BLUE
4
OFF
5
PURPLE
6
PURPLE
7
OFF
8
RED
9 (HIGHEST)
RED
AVERTISSEMENT
!
Pour éviter les blessures ou des dommages
NE JAMAIS régler la force pour compenser des
dommages, y compris une porte mal équilibrée, un rail
de porte coinçant ou des ressorts cassés.
Tous les mois, EFFECTUEZ LE TEST D'INVERSION AU
CONTACT.
CAUTION
!
NE réglez PAS la force à un niveau supérieur à ce qui est
nécessaire pour permettre un fonctionnement normal de
porte.
!
Round LED
BLUE
OFF
BLUE
PURPLE
OFF
PURPLE
RED
OFF
RED
RED
PRESS & RELEASE
See Chart for
Force level
indicators.
Press PRGM to
lock settings
27