Dimensions ( unit: mm )
1. SI unit for SV series valves ( EX500-S 01 )
79.4
68.5
2. SI unit for VQC series valves
( EX500-Q 01 )
80.3
64.4
( EX500-Q 02 )
66
80.3
64.4
84.8
22
28.6
28
0
1
10.5
36
0
1
10.5
44

Mounting/Wiring

The mounting and removing methods of SI unit are as shown below.
Supply/exhaust block
assembly
SI Unit for SV Series Valves ( EX500-S
M3
10: 2 pcs.
( Hexagon socket head cap
screw ( with spring washer ))
SI Unit for VQC Series Valves ( EX500-Q
NOTE
Hold with hands so that there will be no gap between SI unit and Air supply/exhaust
block assembly, and tighten the screws. Be sure to tighten each screw by specified
tightening torque. ( Tightening torque: 0.6Nm )
For branch wiring method, refer to subsection "Wiring" ( page 9 ) of section "EX500"
Note 1
in this manual. As the power to output devices such as solenoid valve is supplied by
branch wiring ( branch cable with M12 connector ), there is no need to supply power
individually.
For mounting/installation methods of solenoid valve, manifold, etc., refer to the
Note 2
catalogs, instruction manuals, technical data, etc. of each valve series.
When connecting general purpose output block only, refer to subsection "Mounting"
( page 33 ) of section "EX9 Series General Purpose Output Block" in this manual.