Huawei OceanStor 2000 V3 Series Features Manual page 85

Hypermetro feature guide for block
Hide thumbs Also See for OceanStor 2000 V3 Series:
Table of Contents

Advertisement

OceanStor V3 Series
HyperMetro Feature Guide for Block
l
l
l
l
l
Issue 05 (2018-01-30)
NOTICE
If Running Status of an added link is Invalid, delete and add the link again.
To ensure data transfer security among storage systems, you are advised to use a device
such as a security gateway to encrypt links to prevent information leakage.
If the version of the local device is different from that of the remote device, you need to
add a remote device on the newer version device. Otherwise the operation may fail.
In HyperMetro scenarios, the two storage arrays need redundant links. Therefore, add
two Fibre Channel links or iSCSI links.
Add an iSCSI Link
a.
Set Link Type to iSCSI.
b.
Set parameters for the iSCSI link.
Table 4-9 iSCSI link parameters
Parameter
Immediate Data
Controller
Local Port
IP Address
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Table 4-9
lists related parameters.
Description
The immediate data
function can speed up
data transfer in the
scenario where iSCSI
replication links transfer
service data between
storage arrays.
Name of the local
storage device's
controller connected to
the remote storage
device.
Local storage device's
Ethernet port connected
to the remote storage
device.
NOTE
This host port cannot be
used for Ethernet port
bonding. Otherwise, the
HyperMetro service fails.
IP address of the
Ethernet port on the
remote storage device.
NOTE
This host port cannot be
used for Ethernet port
bonding. Otherwise, the
HyperMetro service fails.
4 Configuration
Setting
[Example]
Enable
[Example]
XXX0.A
[Example]
XXX0.A0.P0
[Example]
192.168.26.12