Huawei OceanStor 2000 V3 Series Features Manual page 104

Hypermetro feature guide for block
Hide thumbs Also See for OceanStor 2000 V3 Series:
Table of Contents

Advertisement

OceanStor V3 Series
HyperMetro Feature Guide for Block
Figure 4-5 Querying UltraPath configurations
Step 3 Optional: (for vSphere) Enable the APD to PDL function of ESXi hosts.
l
l
l
1.
2.
Issue 05 (2018-01-30)
NOTE
The APD to PDL function is disabled by default.
If ESXi hosts are in non-cluster deployment, skip this operation.
If ESXi hosts are in cluster deployment and the storage system version is
V300R006C00SPC100 or later, skip this operation.
If ESXi hosts are in cluster deployment and the storage system version is earlier than
V300R001C00SPC100, perform the following steps.
Run the esxcli upadm set apdtopdl —m on command.
Run the esxcli show upconfig command to view the configuration result. If APD to
PDL Mode is on, the APD to PDL function of ESXi hosts is enabled.
vSphere Security documentation for more information
~ # esxcli upadm show upconfig
===============================================================
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Configuration
96

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents