F-## Fundamental Parameters - GE AF-650 GP Operating Instructions Manual

General purpose drive high power 460/575/690v 125hp and above
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

How to Program

4.2.2 F-## Fundamental Parameters

Par. No. #
Parameter description
F-0#
F-01
Frequency Setting 1
F-02
Operation Method
F-03
Max Output Frequency 1
F-04
Base Frequency
F-05
Motor Rated Voltage
F-07
Accel Time 1
F-08
Decel Time 1
F-09
Torque Boost
F-1#
F-10
Electronic Overload
F-11
Motor External Fan
F-12
Motor Thermistor Input
F-15
Motor Speed High Limit [Hz]
F-16
Motor Speed Low Limit [Hz]
F-17
Motor Speed High Limit [RPM]
F-18
Motor Speed Low Limit [RPM]
F-2#
F-22
Start Speed [RPM]
F-23
Start Speed [Hz]
F-24
Holding Time
F-25
Start Function
F-26
Motor Noise (Carrier Freq)
F-27
Motor Tone Random
F-28
Dead Time Compensation
F-29
Start Current
F-3#
F-37
Adv. Switching Pattern
F-38
Overmodulation
F-4#
F-40
Torque Limiter (Driving)
F-41
Torque Limiter (Braking)
F-43
Current Limit
F-5#
F-50
Reference Range
F-51
Reference/Feedback Unit
F-52
Minimum Reference
F-53
Maximum Reference
F-54
Reference Function
F-6#
F-62
Catch up/slow Down Value
F-64
Preset Relative Reference
Relative Scaling Reference
F-68
Resource
F-9#
F-90
Step Size
F-91
Accel/Decel Time
F-92
Power Restore
F-93
Maximum Limit
AF-650 GP High Power Operating Instructions
Default value
4-set-up
ExpressionLimit
All set-ups
[0] Linked to Hand /
Auto
All set-ups
132.0 Hz
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
[0] No protection
All set-ups
[0] No
All set-ups
[0] None
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0.0 s
All set-ups
[2] Coast/delay time
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
[1] On
All set-ups
0.00 A
All set-ups
ExpressionLimit
All set-ups
[1] On
All set-ups
ExpressionLimit
All set-ups
100.0 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Sum
All set-ups
0.00 %
All set-ups
0.00 %
All set-ups
[0] No function
All set-ups
0.10 %
All set-ups
1.00 s
All set-ups
[0] Off
All set-ups
100 %
All set-ups
Change during
Conver-
operation
sion index
TRUE
-
TRUE
-
FALSE
-1
FALSE
0
FALSE
0
TRUE
-2
TRUE
-2
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-1
TRUE
-1
TRUE
67
TRUE
67
TRUE
67
TRUE
-1
TRUE
-1
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-2
TRUE
-
FALSE
-
TRUE
-1
TRUE
-1
TRUE
-1
TRUE
-
TRUE
-
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-
TRUE
0
Type
Uint8
Uint8
Uint16
4
4
Uint16
Uint16
Uint32
Uint32
Int16
Uint8
Uint16
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
Uint8
Uint8
Uint16
Uint16
Uint32
Uint8
Uint8
Int32
Int32
Uint8
Int16
Int32
Uint8
Uint16
Uint32
Uint8
Int16
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents