Sp-## Special Functions - GE AF-650 GP Operating Instructions Manual

General purpose drive high power 460/575/690v 125hp and above
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

How to Program

4.2.8 SP-## Special Functions

Par. No. #
Parameter description
SP-0#
SP-00
Fault Level
SP-1#
4
4
SP-10
Line failure
SP-11
Line Voltage at Input Fault
SP-12
Function at Line Imbalance
SP-13
Mains Failure Step Factor
SP-2#
SP-23
Typecode Setting
SP-24
Trip Delay at Current Limit
SP-25
Trip Delay at Torque Limit
SP-26
Trip Delay at Drive Fault
SP-28
Production Settings
SP-29
Service Code
SP-3#
SP-30
Current Lim Cont, Proportional Gain
SP-31
Current Lim Contr, Integration Time
SP-32
Current Lim Ctrl, Filter Time
SP-35
Stall Protection
SP-4#
SP-40
VT Level
SP-41
Energy Savings Min. Magnetisation
SP-42
Energy Savings Min. Frequency
SP-43
Motor Cosphi
SP-5#
SP-50
RFI Filter
SP-51
DC Link Compensation
SP-52
Fan Operation
SP-53
Fan Monitor
SP-55
Output Filter
SP-56
Capacitance Output Filter
SP-57
Inductance Output Filter
SP-59
Actual Number of Inverter Units
SP-6#
SP-63
Option Supplied by External 24VDC
SP-7#
Accel Time 1 S-ramp Ratio at Accel.
SP-71
Start
Accel Time 1 S-ramp Ratio at Accel.
SP-72
End
Decel Time 1 S-ramp Ratio at Decel.
SP-73
Start
Decel Time 1 S-ramp Ratio at Decel.
SP-74
End
SP-76
Accel/Decel Time 2 Type
Accel Time 2 S-ramp Ratio at Accel.
SP-79
Start
66
AF-650 GP High Power Operating Instructions
Default value
ExpressionLimit
[0] No function
ExpressionLimit
[0] Trip
1.0 N/A
ExpressionLimit
60 s
60 s
ExpressionLimit
[0] No action
0 N/A
100 %
0.020 s
1.0 ms
[1] Enabled
66 %
ExpressionLimit
10 Hz
ExpressionLimit
[1] On
[1] On
[0] Auto
[1] Warning
[0] No Filter
2.0 uF
7.000 mH
ExpressionLimit
[1] Yes
50 %
50 %
50 %
50 %
[0] Linear
50 %
4-set-up
Change
Conver-
during
sion index
operation
1 set-up
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-1
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
0
Int32
0
Uint16
-3
Uint16
-4
Uint16
-
Uint8
0
Uint8
0
Uint8
0
Uint8
-2
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-7
Uint16
-6
Uint16
0
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
0
Uint8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents