General Specifications
Control card, USB serial communication:
USB standard
USB plug
Connection to PC is carried out via a standard host/device USB cable.
The USB connection is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
The USB ground connection is not galvanically isolated from protection earth. Use only an isolated laptop as PC connection to
the USB connector on the drive.
Relay outputs:
Programmable relay outputs
Relay 01 Terminal number
Max. terminal load (AC-1)
5
5
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Relay 02 Terminal number
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Max. terminal load (AC-1)
Max. terminal load (AC-15)
Max. terminal load (DC-1)
Max. terminal load (DC-13)
Min. terminal load on 1-3 (NC), 1-2 (NO), 4-6 (NC), 4-5 (NO)
Environment according to EN 60664-1
1) IEC 60947 part 4 and 5
The relay contacts are galvanically isolated from the rest of the circuit by reinforced isolation (PELV).
Cable lengths and cross sections:
Max. motor cable length, screened/armoured
Max. motor cable length, unscreened/unarmoured
Maximum cross section to control terminals, flexible/ rigid wire without cable end sleeves
Maximum cross section to control terminals, flexible wire with cable end sleeves
Maximum cross section to control terminals, flexible wire with cable end sleeves with collar
Minimum cross section to control terminals
Control card performance:
Scan interval
Control characteristics:
Resolution of output frequency at 0 - 1000Hz
Repeat accuracy of Precise start/stop (terminals 18, 19)
System response time (terminals 18, 19, 27, 29, 32, 33)
Speed control range (open loop)
Speed control range (closed loop)
Speed accuracy (open loop)
Speed accuracy (closed loop), depending on resolution of feedback device
Torque control accuracy (speed feedback)
All control characteristics are based on a 4-pole asynchronous motor
84
AF-650 GP High Power Operating Instructions
1)
on 1-3 (NC), 1-2 (NO) (Resistive load)
1)
(Inductive load @ cosφ 0.4)
1)
on 1-2 (NO), 1-3 (NC) (Resistive load)
1)
(Inductive load)
1)
on 4-5 (NO) (Resistive load)
1)
on 4-5 (NO) (Inductive load @ cosφ 0.4)
1)
on 4-5 (NO) (Resistive load)
1)
on 4-5 (NO) (Inductive load)
1)
on 4-6 (NC) (Resistive load)
1)
on 4-6 (NC) (Inductive load @ cosφ 0.4)
1)
on 4-6 (NC) (Resistive load)
1)
on 4-6 (NC) (Inductive load)
1.1 (Full speed)
USB type B "device" plug
1-3 (break), 1-2 (make)
4-6 (break), 4-5 (make)
24V DC 10mA, 24V AC 20mA
over-voltage category III/pollution degree 2
1.5mm
1mm
0.5mm
0.25mm
1:100 of synchronous speed
1:1000 of synchronous speed
30 - 4000rpm: error ±8rpm
0 - 6000rpm: error ±0.15rpm
max error±5% of rated torque
2
240V AC, 2 A
240V AC, 0.2A
60V DC, 1A
24V DC, 0.1A
400V AC, 2A
240V AC, 0.2A
80 V DC, 2A
24V DC, 0.1A
240V AC, 2A
240V AC, 0.2A
50V DC, 2 A
24V DC, 0.1A
150m
300m
2
/16 AWG
2
/18 AWG
2
/20 AWG
2
/ 24 AWG
1ms
± 0.003Hz
≤± 0.1ms
≤ 2ms