GE AF-650 GP Operating Instructions Manual page 94

General purpose drive high power 460/575/690v 125hp and above
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

General Specifications
Mains Supply 3 x 525-690V AC
AF-650 GP
Heavy Duty/Light Duty*
Max. input current
* Heavy Duty = 160% torque during 60 sec., Light Duty = 110% torque during 60 sec.
1) For type of fuse see section Fuses.
2) American Wire Gauge.
3) Measured using 5 m screened motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within +/-15% (tolerence relates to
variety in voltage and cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to
the power loss in the drive and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
Keypad and typical control card power consumptions are included. Further options and customer load may add up
to 30W to the losses. (Though typical only 4W extra for a fully loaded control card, or options for slot A or slot B,
each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be
allowed for (+/-5%).
AF-650 GP High Power Operating Instructions
Typical Shaft output at 550V [kW]
Typical Shaft output at 575V [hp]
Typical Shaft output at 690V [kW]
IP21/Nema 1 and IP54/Nema 12 Drive
Types without/with options cabinet
Output current
Continuous (at 550V) [A]
Intermittent (60 sec overload)
(at 550V) [A]
Continuous (at 575/690V) [A]
Intermittent (60 sec overload)
(at 575/690V) [A]
Continuous KVA (at 550V) [KVA]
Continuous KVA (at 575V) [KVA]
Continuous KVA (at 690V) [KVA]
Continuous (at 550V ) [A]
Continuous (at 575V) [A]
Continuous (at 690V) [A]
2
2)
Max. cable size, motor [mm
(AWG
)]
2
Max. cable size, mains 62 [mm
(AWG
2
Max. cable size, mains 64 [mm
(AWG
2
Max. cable size, loadsharing [mm
2)
(AWG
)]
2
2)
Max. cable size, brake [mm
(AWG
)
1
Max. external mains fuses [A]
Estimated power loss
4)
at 600V [W]
Estimated power loss
4)
at 690V [W]
63/64 Max added losses CB or Disconnect
& Contactor
Max panel options losses
Weight,
Unit Size IP21, IP54 [kg]
Weight, Rectifier Module [kg]
Weight, Inverter Module [kg]
4)
Efficiency
Output frequency
Heatsink overtemp. trip
Power card ambient trip
1250 hp
HD
LD
750
850
1050
1150
900
1000
62/64
988
1108
1482
1219
945
1060
1418
1166
941
1056
941
1056
1129
1267
962
1079
920
1032
920
1032
(12x300 mcm)
2)
)]
(8x500 mcm)
2)
)]
(8x900 mcm)
(4x250 mcm)
(6x350 mcm)
1600
13755
15592
14457
16375
556
665
1246/ 1541
136
102
1350 hp
HD
LD
850
1000
1150
1350
1000
1200
62/64
1108
1317
1662
1449
1060
1260
1590
1386
1056
1255
1056
1255
1267
1506
1079
1282
1032
1227
1032
1227
12x150
8x240
8x456
4x120
6x185
2000
15107
18281
15899
19207
634
863
400
1246/ 1541
136
102
0.98
0-500 Hz
85°C
68 °C
5
5
93