1
Compact version
temperature table
Prosonic 92F**-*****P*****A/W
Prosonic 92F**-*****P*****H/K
Remote version
temperature table
Prosonic 92F**-*****P*****A/W
Prosonic 92F**-*****P*****H/K
Prosonic 92F**-*****P*****A/W
Prosonic 92F**-*****P*****H/K
Design of the measuring
system
12
Outputs/inputs (Item No. 18 in type code)
*
Approval
A, W
Cl. I, Groups ABCD
Cl. II, Groups EFG
Cl. III
Cl. I, Zone 1, AEx/Ex d [ia] IIC T6 - T1
H, K
Cl. I, Groups ABCD
Cl. II, Groups EFG
Cl. III
Cl. I, Zone 1, AEx/Ex d [ia] IIC T4 - T1
!
Note!
A detailed explanation of these values with regard to the inputs and outputs available, as well as a description
of the associated terminal assignments and connection data is provided on Page 14 onwards.
Medium temperature range Tmed [°C] depending on the device version (see Page 11) and the ambient
temperature range T
:
a
T
a
T6
[°C]
(85 °C)
–40 to +40
–40 to 80
–40 to +55
–
–40 to +60
–
–40 to +60
–
Sensor
Medium temperature range Tmed [°C] depending on the device version (see Page 11) and the ambient
temperature range T
:
a
T
a
T6
[°C]
(85 °C)
–40 to +60
–40 to 80
–40 to +80
–
–40 to +80
–
Transmitter
Ambient temperature range Ta [°C] depending on the device version (see Page 11):
T6
T5
(85 °C)
(95 °C)
40
–40 to 55
–
–
Compact/remote version design
A
B
a
b
d
C
c
Fig. 2
T
med
T5
T4
(95 °C)
(135 °C)
–40 to 95
–40 to 130
–40 to 95
–40 to 130
–
–40 to 130
–
–40 to 130
T
med
T5
T4
(95 °C)
(135 °C)
–40 to 95
–40 to 130
–40 to 95
–40 to 130
–
–40 to 130
T
med
T4
T3
(135 °C)
(200 °C)
–40 to 80
–40 to 80
–40 to 80
–40 to 80
A
Transmitter housing (compact version)
a
Screw terminal for connecting to potential matching system
S
WARNUNG
AVERTISSEMENT
B
Connection housing transmitter (remote version)
b
Screw terminal for connecting to potential matching system
C
Connection housing sensor (remote version)
c
Screw terminal for connecting to potential matching system
d
Remote version connecting cable
– Connecting cable cable specifications Page 13
– Cable entries Page 13
A0004031
– Terminal assignment and connection data Page 14
Proline Prosonic Flow 92F
T3
T2
(200 °C)
(300 °C)
–40 to 195
–40 to 200
–40 to 195
–40 to 200
–40 to 195
–40 to 200
–40 to 195
–40 to 200
T3
T2
(200 °C)
(300 °C)
–40 to 195
–40 to 200
–40 to 195
–40 to 200
–40 to 195
–40 to 200
T2
(300 °C)
–40 to 80
–40 to 80
Endress+Hauser
T1
(450 °C)
–40 to 200
–40 to 200
–40 to 200
–40 to 200
T1
(450 °C)
–40 to 200
–40 to 200
–40 to 200
T1
(450 °C)
–40 to 80
–40 to 80
Need help?
Do you have a question about the Proline Prosonic Flow 92F and is the answer not in the manual?
Questions and answers