Compact Version Temperature Table; Remote Tabelle Version Temperature Table; Design Of The Measuring System - Endress+Hauser Proline Prosonic Flow 92F Series Safety Instructions

Table of Contents

Advertisement

Available languages

Available languages

0
ATEX II3G
Compact version
temperature table
92F**-*****H*****A/W
92F**-*****H*****H/K
Remote tabelle version
temperature table
92F**-*****H*****A/W
92F**-*****H*****H/K
92F**-*****H*****A/W
92F**-*****H*****H/K
Design of the measuring
system
16
Outputs/inputs (Item No. 18 in type code)
*
Approval
0 II3G EEx nA II T1-T6 resp. 0 II3G EEx nL IIC T1-T6
A, W
0 II3G EEx nA II T1-T4 resp. 0 II3G EEx nL IIC T1-T4
H, K
!
Note!
A detailed explanation of these values with regard to the inputs and outputs available, as well as a description
of the associated terminal assignments and connection data is provided on Page 17 onwards.
Medium temperature range T
med
temperature range T
:
a
T
a
T6
[°C]
(85 °C)
–40... +40
–40...+80
–40... +55
–40... +60
–40... +60
Sensor
Medium temperature range T
med
temperature range T
:
a
T
a
T6
[°C]
(85 °C)
–40... + 60
–40...+80
–40... + 80
–40... + 80
Transmitter
Ambient temperature range Ta [°C] depending on the device version (see Page 15):
T6
T5
(85 °C)
(100 °C)
–40...+40
–40...+55
Compact/remote version design
A
B
a
b
d
C
c
Fig. 2
[°C] depending on the device version (see Page 15) and the ambient
T
med
T5
T4
(100 °C)
(135 °C)
–40...+95
–40...+130
–40...+130
[°C] depending on the device version (see Page 15) and the ambient
T
med
T5
T4
(100 °C)
(135 °C)
–40...+95
–40...+130
–40...+130
T
a
T4
T3
(135 °C)
(200 °C)
–40...+80
–40...+80
–40... +80
–40... +80
A
Transmitter housing (compact version)
a
Screw terminal for connecting to potential matching system
B
Connection housing transmitter (remote version)
b
Screw terminal for connecting to potential matching system
C
Connection housing sensor (remote version)
c
Screw terminal for connecting to potential matching system
d
Remote version connecting cable
– Connecting cable cable specifications  Page 17
– Cable entries  Page 17
A0006026
– Terminal assignment and connection data  Page 18
Proline Prosonic Flow 92F
T3
T2
(200 °C)
(300 °C)
–40...+195
–40...+200
–40...+195
–40...+200
T3
T2
(200 °C)
(300 °C)
–40...+195
–40...+200
–40...+195
–40...+200
T2
(300 °C)
–40...+80
–40... +80
Endress+Hauser
T1
(450 °C)
–40...+200
–40...+200
T1
(450 °C)
–40...+200
–40...+200
T1
(450 °C)
–40...+80
–40...+80

Advertisement

Table of Contents
loading

Table of Contents