Accessories, Optional; Status Led's - King gates Star 224 Manual

Swing gate control unit for 1 or 2 24 vdc jet motors / modus motors
Hide thumbs Also See for Star 224:
Table of Contents

Advertisement

15 - OPTIONAL ACCESSORIES
HAZ – HAZARD LIGHT output: terminals 10, 19; 12 VDC Max 15W. (0.6Amp); for connection of hazard light.
Turns on a second before the wings move. DipSwitch-5 setting: ON: Flashing / / OFF: steady on
ANTENNA input : terminals 1,2 - for increasing reception range connect an external antenna (Item code: ANT 433)
and remove internal antenna (the wire from the terminal)
TX – MOTION INDICATION LIGHT output: terminal 8, 9 – 12 Vdc Max 3W (0.25W)
Gate opening
>> Light flashes //
Gate open or closed (stand still)
also used for the Safety Auto Test mode (section 14).
ELECTRIC LATCH LOCK output – terminals 10, 11; 12Vdc MAX 15W (1.25Amp)
BACKUP BATTERY KIT
Backup battery kit available in two options:
2 x 2.3 A/H (Buffer) internal batteries and charger provide emergency power for about 3 hours
2 x 7 A/H batteries and charger provide emergency power for about 8 hours.
COURTESY LIGHT output –optional card connected to HAZ terminals 10,11
Voltage free (dry) contact Max 250Vac 500W ** Time range: (0) to 120 Seconds

16 - STATUS LED'S

SET Yellow LED
FLASHING for 5 seconds when power is turned on.
ON > during Gate Travel Learning
OFF>when unit operates normally
RADIO Red LED
OFF >the control unit is functioning normally
FLASHING briefly when a remote transmits
ON > the unit is ready to store a new remote to memory
FLASHING fast while deleting all remotes from memory
FLASHING continuously fast > memory card is faulty
FLASHES continuously slowly >memory card is full
PH Red LED
ON >photo-sensor connected properly (if safety devices are not connected, the links must be in place, Section 2)
OFF> Safety (photocell) sensor is triggered (or not correctly installed)
START Green LED
ON >START command received contact close (shorted) terminal 12
OFF> no START command
ST Red LED
ON > the STOP input (terminal 14) is closed (shorted)
OFF> the STOP input (terminal 14) is opened
ER red LED
ON or FLASHING > an error occurs (see Trouble shooting section 18)
ON or FLASHING > Travel learning needs to be done see sec.9
OFF
> the control unit is working normally
8
Gate closing >> Fast flashing
>> no output

Advertisement

Table of Contents
loading

This manual is also suitable for:

Star m 224

Table of Contents