3 - SETTING THE DIPSWITCHES
- DipSwitches settings will only take effect after the system has reached the end of a cycle. i.e.
when the gate closed or when the system has been reset (power off, battery and mains)
DIP sw.1 needs to be set BEFORE the gate travel learning
DS-1: Motor
ON
OFF
DS-2: STEP
DS-3: AUTO
ON
ON
ON
OFF
OFF
ON
OFF
OFF
DS-4: Photo sensor-2
ON
OFF
DS-5: Hazard Light
ON
OFF
DS-6: Kick-back
ON
OFF
DS-7: Close After Photo
ON
OFF
DS-8: Remote Control
Programming
ON
OFF
4 - LINEAR POTENTIOMETERS
- Adjustments to the potentiometers will only take effect after the system has reached to the end of a cycle,
i.e. when the gate closed or when the system has been reset (power off). Make sure that you let the adjustments
take effect before readjusting.
- Adjusting the POWER potentiometers will require repeating the Automatic gate travel learning
POWER AND SPEED
pushing-force and for fine control over the speed (basic speed is determined by DipSwitch-1).
Adjustment range is 30% to 100%. Adjust this potentiometer to have enough power to push against
a 15 -35kg object that is 2 meters from the wing's hinges. (If the wing(s) are too sensitive to obstacles
increase (+) the OBSTACLE potentiometer slightly)
Typical position - near maximum
Remember: adjusting the power pot. will take effect only after doingthe gate travel learning (sec.9)
OBSTACLE
potentiometer is the anti-crush control. This determines the motor's pushing force limit and
the time it takes the motor(s) to cut-out after hitting an obstacle. Increase (+) this adjustment when more
force is needed. Eg. for gates made of full steel, cast iron, colorbond (sheet metal), and for gates in windy
areas. Cut out range time is 0.1 to 3 seconds
- For windy arias, wooden and colorbond gates – increase the obstacle level slightly
- This potentiometer also controls the pressure against the travel stoppers. Check manual override operation after adjusting
this potentiometer
Typical position - near maximum
PAUSE
potentiometer determines the delay time at the open position before automatically closing.
(for auto-closing modes only). The delay range is 1 to 90 seconds.
- Remember: let the cycle finish before readjusting
DELAY
between the wings in opening and closing. This potentiometer controls the delay between MOT 1 and MOT 2
(wing 1 and wing 2). Use this delay when wings overlap or when using an electric lock. The delay range is 0 to 15 seconds.
- Remember for single wing gates - this potentiometer should be set to 0 (zero).
4
Motor type (to set before gate travel learning)
Folding arm Modus,Minimodus
Linear, Jet, Couper
Operation mode setting
Auto-Closing with intervention by remote /command
Step-by-step: open / stop / close / stop ....
Fully Automatic, always close, (condominium)
Open / close /open (no stop when opening)
PHO2 input - terminal 17, setting
Photo-sensor intervenes in opening and closing
Safety edge operation
Hazard Light output (terminals 10 & 19) setting
Connected light will flash during the cycle
Connected light will be steady on during the cycle
Kick-back (Water hammer) on start
Before opening, the gate shortly pushes to closing (for lock release).for hydraulic rams
Kickback is disabled
Close immediately after vehicle clears the photocell
Gate closes immediately once photo-sensor is cleared
Close after Photo disabled
Remote Control Programming setting
vehicle / pedestrian access (see sections 5, 6 and 11)
Vehicle (full) opening
Pedestrian opening
potentiometer adjusts the force and speed of the motor(s). Use this to adjust the