Pedestrian Access Deleting All Remote Control Codes; Advance Features; Safety Devices - Detailed Descriptions - King gates Star 224 Manual

Swing gate control unit for 1 or 2 24 vdc jet motors / modus motors
Hide thumbs Also See for Star 224:
Table of Contents

Advertisement

12 - RESET THE PEDESTRIAN OPENING GAP TO DEFAULT SETTING
1) Make sure that the gate is in the closed position
2) Press the SET button for 2 seconds
3) Press the START button
4) Press the SET button
13 - DELETING PEDESTRIAN ACCESS BY REMOTE CONTROL
1) Make sure that the gate is in the closed position
2) Press the SET button for 2 seconds
3) Press the START button
4) Press the SET button
Pedestrian access by remote control deleted (push button command terminal 15 still active)

ADVANCE FEATURES

14 - SAFETY DEVICES DETAILED DESCRIPTION
PHO1- SAFETY DEVICES IN CLOSING
Input PHO1 (terminal 16 and 18) is used for connecting photo-sensors as safety devices to intervene during closing.
PHO2: SAFETY DEVICES IN OPENING AND CLOSING
Input PHO2 (terminals 16 and 17) intervene both in closing and in opening
There are two options determined by DipSwitch 4:
DipSwitch 4 ON: if trigged by safety device >> gate stops and when path is cleared keeps going
DipSwitch 4 OFF: (for Safety Edge in Opening):
Trigged in opening
Trigged in closing
NOTE:
If more than one pair of photo-sensors is used, it is
recommended to have the position of the transmitters
and receivers alternated between the pair,
in order to avoid cross triggering.
SAFETY AUTO TEST
The Auto safety test is recommended in Europe. The control unit has a Safety Device Test mode
to check the operation of the devices connected to inputs PHO1 (terminals)
and PHO2 (terminals).
ENTER THE SAFETY DEVICE TEST:
1) First connect the Photo-sensor's +VE end to the TX input (terminal 20) instead of the VA input (terminal 19),
for which it should be connected during normal operation.
2) Press the RADIO button for 2 sec
3) Press the SET button 4 times
4) Wait 10 seconds
EXIT THE SAFETY AUTO TEST MODE (if error LED on press the SET button, and wait unit the SET LED turns off) then:
1) Press the RADIO button for 2 seconds
2) Press the START button once
3) Wait 10 seconds
NOTE: Entering the test with the safety devices not properly connected will cause the unit to malfunction.
To determine whether the unit is in the test mode press the RADIO button for 3 seconds: if the RADIO LED turns on
then the self-test is disabled. If both the red RADIO led and the yellow SET led turn on then the test is active.
>> SET LED begins to flash
>> SET LED turns steady on
>> SET LED flashes rapidly and turns off
Pedestrian opening gap reset
>> SET LED begins to flash
>> SET LED turns steady on
>> SET LED flashes rapidly and turns off
>> stops and closes for 2 seconds
>> no effect
>> RADIO-LED Red turns on
>> SET LED Yellow turns on
>> SET LED and RADIO LED both turn off
Safety Auto Test is now activated
>>SET LED and red RADIO LED both turn on
>> SET LED turns off
>> RADIO LED turns off
Safety Auto Test is now deactivated
Crossing safety receivers
& transmitters
RX
TX
TX
RX
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Star m 224