2 - ELECTRICAL CONNECTIONS
Cable length and cross section
- If the distance between the control unit and the grounding system is more than 30m, then it is necessary to install an
electric discharger near the control unit
- Cables used for low-voltage features must be at least 0.25 mm2 for distance up to 30meters
- Use shielded (screened) cables that are at least 0.5mm2 for distance 30 -100meter
- Do not connect cables in underground boxes or inside conduits
PHOTOCELL CONNECTION - VIKY SERIES
CLOSING PHOTOCELL
CONNECTION
+
-
+ -
RX
TX
NC
C
NO
19 18
16
18
19 18
PHOTO 1
POWER SUPPLY (N)
24O VAC(L)
13. COMMON for Terminals 12, 14, 15
15. Pedestrian opening contact PED
18. COM. for Terminals 9, 19 and 20 (OV)
20. INDICATION LIGHT (12Vdc max 3W)
NOTE:
- All connections to the board must be voltage free contacts
("dry Contacts")
- For motors without limit switches, terminals 3,4,5,6 and 7
are not used and must not be bridged (linked)
- The unit comes with safety devices' inputs (terminals 16
and 17) and the STOP input (terminal 4) all bridged (linked)
to the COM (T13, 18)
- When connecting safety or STOP devices, remove the links
from these terminals.
- For single wing gates, use only MOT1. Single / double
motor set up done automatically with the gate travel learning
OPENING PHOTOCELL
CONNECTION
+
-
RX
TX
NC
C
NO
19 18 17
18
PHOTO 2
FUSE 3.15A
1. ANTENNA in
2. ANTENNA shield
3. Opening limit switch motor 1
4. Closing limit switch motor 1
5. Terminals 3,4,6,7 common
6. Opening limit switch motor 2
7. Closing limit switch motor 2
8. ELECTRIC LOCK 12V
9. 24Vdc power
10. HAZARD LIGHT 12 V 100mA
11. OV
12. PUSH BUTTON START
14. STOP
16. Safety 1 PHO1
17. Safety 2 PHO2
19. 12Vdc power
21. 22.23.
+ -
TRANSFORMER
19 18
MOTOR 1
MOTOR 2
Motor wires
open inward:
White 24, 26
Brown 25,27
ANT
GND
FOP1
FCC1
COM
FOP2
FCC2
LOCK
LOCK
24Vdc
HAZ
COM
START
COM
STOP
PED
PHO1
PHO2
COM
12Vdc
TEST
ORANGE
BLUE
BLACK
27 26 25 24 23 22 21
MOT2
MOT1
CONTROL UNIT
RECEIVER
ORIENTATION
12V 2A FUSE
2A
MEMORY
CARD
ORIENTATION
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Star m 224

Table of Contents