I/O CONNECTIONS:
• CN1 CONNECTOR – 10 pins:
It is situated on the upper part of the back panel.
PIN
NOME
NOT
1
USED
COM
Common pin. Signals must be taken between this pin and the respective signal pins (pin 6, 7
2
0V
e 8).
DC
Error signal: it activates every time an error occurs.
3
ERROR
The error signal resets after 3 beep sounds.
Signal is 24VDC
Lever signal: when lever is pressed or when the start is remote. No signal during unscrewing
4
LEVER
cycle. It resets after their release. Signal is 24VDC
Torque signal. It activates every time the torque is reached and it resets when the lever or
5
TORQUE
remote start is released . Signal is 24VDC
T&A
External input for making the control unit start to count the angle. It can be only used in
6
INPUT
A/IN and T/IN mode (see T&A paragraph)
STOP
Remote motor stop. If it's activated the message "STOP MOTOR ON" appears on the
7
MOTOR
display. T he motor will stop and won't start working again as long as the contact is closed
8
REVERSE Remote motor start with torque control while unscrewing.
9
START
Remote start with torque control while screwing.
COM
Common pin. The desired function is activated through a contact between this pin and one
10
0V
of the other pins (pin 2, 3, 4, 5). This pin is connected to 0VDC and to the ground
DC
Manual EDU 2AE/TOP e EDU 2AE/TOP/TA Rev.0
FUNZIONE
OUTPUT
INPUT
Pagina 15
Need help?
Do you have a question about the EDU 2AE/TOP and is the answer not in the manual?
Questions and answers