9.6
Main PCB ASSY
(1) Check the presence or absence of the copper seal on the main PCB upper shield.
Copper seal
The presence case of the copper seal
(2) Disconnect all harnesses and flat cable connected to the main PCB ASSY.
HARNESS ROUTING: Refer to
Main PCB upper shield
Main PCB ASSY
Front cover sensor
harness
Document detection / Document
scanning position sensor harness
"1. Main PCB
Fig. 3-11
Paper feed / Eject jam sensor harness
Multi feeding sensor harness (Sent)
Multi feeding sensor
harness (Receive)
Fig. 3-12
ASSY".
3-20
Paper feed
motor harness
Feed motor
harness
Panel flat cable
First side CIS
flat cable
Confidential