NB!
The decel ramp time is automatically adjusted to avoid tripping of the frequency converter.

C-05 Multi-step Frequency 1 - 8

Array [8]
Range:
0.00 %*
[-100.00 - 100.00 %]
7

C-30 Frequency Command 2

Option:
[0]
No function
[1]
Analog input 53
[2]
Analog input 54
[7]
Pulse input 29
[8]
Pulse input 33
[20] *
Digital Potentiometer
[21]
Analog input X30/11
[22]
Analog input X30/12
[23]
Analog Input X42/1
[24]
Analog Input X42/3
[25]
Analog Input X42/5
[30]
Ext. Closed Loop 1
[31]
Ext. Closed Loop 2
[32]
Ext. Closed Loop 3

C-40 Semi-Auto Jump Freq Set-up

Option:
[0] *
Off
[1]
Enabled
98
Function:
Enter up to eight different preset references (0-7) in this parameter, using array programming. The preset
reference is stated as a percentage of the value Ref
see par. CL-14 Maximum Reference/Feedb.). When using preset references, select Preset ref. bit 0 / 1 / 2
[16], [17] or [18] for the corresponding digital inputs in parameter group E-## Digital Inputs.
Function:
Select the reference input to be used for the second reference signal. par. F-01 Frequency Setting 1, par.
C-30 Frequency Command 2 and par. C-34 Frequency Command 3 define up to three different reference
signals. The sum of these reference signals defines the actual reference.
This parameter cannot be adjusted while the motor is running.
(OPCGPIO)
(OPCGPIO)
(OPCAIO)
(OPCAIO)
(OPCAIO)
Function:
No function
Starts the Semi-Automatic Bypass set-up and continue with the procedure described above.
AF-600 FP High Power Operating Instructions
(par. F-53 Maximum Reference, for closed loop
MAX