Dependent On Parameter; Can Not Be Auto Reset Via Par. H-04 Auto-Reset (Times); Alarm Word And Extended Status Word - GE AF-600 FP Operating Instructions Manual

Fan and pump drive (460v/575v 150hp and above)
Hide thumbs Also See for AF-600 FP:
Table of Contents

Advertisement

No.
Description
244
Heatsink temp
245
Heatsink sensor
246
Pwr.card supply
247
Pwr.card temp
248
Illegal PS config
250
New spare part
251
New Model Number
Table 9.3: Alarm/Warning code list
(X) Dependent on parameter

1) Can not be Auto reset via par. H-04 Auto-Reset (Times)

A trip is the action when an alarm has appeared. The trip will coast the motor and can be reset by pressing the reset button or make a reset by a digital input (Par.
E-1# [1]). The origin event that caused an alarm cannot damage the frequency converter or cause dangerous conditions. A trip lock is an action when an alarm
occurs, which may cause damage to frequency converter or connected parts. A Trip Lock situation can only be reset by a power cycling.
LED indication
Warning
Alarm
Trip locked

Alarm Word and Extended Status Word

Bit
Hex
0
00000001
1
00000002
2
00000004
3
00000008
4
00000010
5
00000020
6
00000040
7
00000080
8
00000100
9
00000200
10
00000400
11
00000800
12
00001000
13
00002000
14
00004000
15
00008000
16
00010000
17
00020000
18
00040000
19
00080000
20
00100000
21
00200000
22
00400000
23
00800000
24
01000000
25
02000000
26
04000000
27
08000000
134217728
28
10000000
268435456
29
20000000
536870912
30
40000000
1073741824
Table 9.4: Description of Alarm Word, Warning Word and Extended Status Word
The alarm words, warning words and extended status words can be read out via serial bus or optional fieldbus for diagnosis. See also par. DR-90 Alarm Word,
par. DR-92 Warning Word and par. DR-94 Ext. Status Word.
Warning
X
yellow
flashing red
yellow and red
Dec
Alarm Word
1
Brake Check
2
Pwr. Card Temp
4
Earth Fault
8
Ctrl.Card Temp
16
Ctrl. Word TO
32
Over Current
64
Torque Limit
128
Motor Th Over
256
Motor Elec. OL Over
512
Inverter Overld.
1024
DC under Volt
2048
DC over Volt
4096
Short Circuit
8192
Inrush Fault
16384
Mains ph. Loss
32768
Auto Tune Not OK
65536
Live Zero Error
131072
Internal Fault
262144
524288
U phase Loss
1048576
V phase Loss
2097152
W phase Loss
4194304
Fieldbus Fault
8388608
24 V Supply Low
16777216
Mains Failure
33554432
1.8V Supply Low
67108864
Brake Resistor
Brake IGBT
Option Change
Drive Restored to Factory
Settings
AF-600 FP High Power Operating Instructions
Alarm/Trip
Alarm/Trip Lock
X
X
X
X
X
X
X
X
X
X
X
X
X
Warning Word
Extended Status Word
Brake Check
Ramping
Pwr. Card Temp
Auto Tune Running
Earth Fault
Start CW/CCW
Ctrl.Card Temp
Slow Down
Ctrl. Word TO
Catch Up
Over Current
Feedback High
Torque Limit
Feedback Low
Motor Th Over
Output Current High
Motor Elec. OL Over
Output Current Low
Inverter Overld.
Output Freq High
DC under Volt
Output Freq Low
DC over Volt
Brake Check OK
DC Voltage Low
Braking Max
DC Voltage High
Braking
Mains ph. Loss
Out of Speed Range
No Motor
OVC Active
Live Zero Error
10V Low
Speed Limit
Fieldbus Fault
24V Supply Low
Mains Failure
Current Limit
Low Temp
Voltage Limit
Unused
Unused
Unused
Parameter Reference
9
163

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents