GE AF-600 FP Operating Instructions Manual page 86

Fan and pump drive (460v/575v 150hp and above)
Hide thumbs Also See for AF-600 FP:
Table of Contents

Advertisement

K-01 Language
Option:
[0] *
English
P-07 Motor Power [kW]
Range:
4.00 kW*
[0.09 - 3000.00 kW]
P-02 Motor Power [HP]
Range:
4.00 hp*
[0.09 - 3000.00 hp]
F-05 Motor Rated Voltage
Range:
400. V*
[10. - 1000. V]
F-04 Base Frequency
Range:
50. Hz*
[20 - 1000 Hz]
NB!
This parameter cannot be adjusted while the motor is running.
P-03 Motor Current
Range:
7.20 A*
[0.10 - 10000.00 A]
NB!
This parameter cannot be adjusted while the motor is running.
P-06 Base Speed
Range:
1420. RPM*
[100 - 60000 RPM]
NB!
This parameter cannot be changed while the motor is running.
Function:
Defines the language to be used in the display.
The frequency converter is delivered with 4 different languages.
Part of Language packages 1 - 4
Function:
Enter the nominal motor power in kW according to the motor nameplate data. The default value corre-
sponds to the nominal rated output of the unit.
This parameter cannot be adjusted while the motor is running. Depending on the choices made in par.
K-03 Regional Settings, either par. P-07 Motor Power [kW] or par. P-02 Motor Power [HP] is made invisible.
Function:
Enter the nominal motor power in HP according to the motor nameplate data. The default value corre-
sponds to the nominal rated output of the unit.
This parameter cannot be adjusted while the motor is running.
Depending on the choices made in par. K-03 Regional Settings, either par. P-07 Motor Power [kW] or par.
P-02 Motor Power [HP] Motor Power is made invisible.
Function:
Enter the nominal motor voltage according to the motor nameplate data. The default value corresponds
to the nominal rated output of the unit.
This parameter cannot be adjusted while the motor is running.
Function:
Select the motor frequency value from the motor nameplate data.
Function:
Enter the nominal motor current value from the motor nameplate data. This data is used for calculating
motor torque, motor thermal protection etc.
Function:
Enter the nominal motor speed value from the motor nameplate data. This data is used for calculating
automatic motor compensations.
AF-600 FP High Power Operating Instructions