Furuno CH-500 Installation Manual page 74

Dual-frequencysearchlight sonar
Hide thumbs Also See for CH-500:
Table of Contents

Advertisement

APPENDIX 2 HOW TO MAKE THE RETRACTION TANK FOR WOODEN VESSEL
Name
Material
Flange-2
SS400
Angle-2
SUS304-CP
Prepare the long holes for the bolt
(Ø14 × 30, 2 locations)
Fixing plate
SUS304-CP
AP-4
Thickness
More than
12.0 mm
C1
C1
I.D: Inside diamater
Pipe O.D: Outside diameter of the PVC pipe
4.0 mm
42
26
4.0 mm
235
Prepare the long holes for the bolt
(Ø14 × 30, 4 locations)
Qty
1
Inside diameter: Max. 259 mm,
Outside diameter: 343 mm
45°
8 × Ø14
4
Welded to the flange-2.
Ø14 × 30 long hole
4
The equal angle iron (L50
available.
32.5
Remarks
Min. Pipe O.D + 20 mm
35
t4.0) is also
(4)
50
R4 - 6