Furuno CH-500 Installation Manual page 54

Dual-frequencysearchlight sonar
Hide thumbs Also See for CH-500:
Table of Contents

Advertisement

2. WIRING
How to connect wires to WAGO connector
Twist
No.
Cable
1
Transducer cable
(06CA10040)
2
FRU-WH-A-15/30/50M
3
DPYCYSLA-2.5*
4
Ground wire (IV-2sq.)
2-8
PRA board 06P0291
FLT board 06P0292
Press downward.
Procedure
1. Twist the cores.
2. Press the terminal opener downward.
Terminal
3. Insert the wire to hole.
opener
4. Remove the terminal opener.
5. Pull the wire to confirm that it is secure.
WAGO
connector
Access point on the raise/lower control unit
PRA board 06P0291: J213
FLT2 board 06P0298: J226
PRA board 06P0291: J212 and TB211
FLT2 board 06P0298: J227
FLT board 06P0292: TB201
Note: For the drain wire of the DPYCYSLA-2.5
cable, fasten to the cable fixing plate.
Ground terminal
Cable clamp
Rubber sleeve
Lock nut
1
2
Terminal opener
3
Fasten the drain wire of the
power cable to the cable
fixing plate. The screw for
the drain wire is pre-attached
to the cable fixing plate.
4
Cable from
Transducer
Transceiver unit
Ship's main (12/24 V
DC)
Ship's ground

Hide quick links: