Page 2
The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN A : JUN 2015 Printed in Japan All rights reserved. A3 : JUL . 22, 2016 Pub. No. OME-13500-A3 (MISU ) CSH-5LM2/CSH-8LM2...
Page 3
How to discard a used battery Some FURUNO products have a battery(ies). To see if your product has a battery(ies), see the chapter on Maintenance. Follow the instructions below if a battery(ies) is used. In the European Union The crossed-out trash can symbol indicates that all types of batteries must not be discarded in standard trash, or at a trash site.
Page 4
Electrical shock can result. Continued use of the equipment can cause fire or electrical shock. Contact a FURUNO agent for service. Do not disassemble or modify the equipment. Fire, electrical shock or serious injury can result.
Page 5
Do not remove any label. Do not exceed 18 knots with the If a label is missing or damaged, contact transducer lowered and do not a FURUNO agent or dealer about exceed 15 knots when lowering or replacement. raising the transducer.
TABLE OF CONTENTS FOREWORD ........................vii SYSTEM CONFIGURATION ..................viii TABLE OF CONTENTS....................iv OPERATIONAL OVERVIEW .................1-1 1.1 Control Unit ........................ 1-1 1.2 Remote Controller (option)..................1-2 1.3 Basic Operating Procedure ..................1-3 1.3.1 Turning on the power ..................1-3 1.3.2 Lowering the transducer................. 1-3 1.3.3 Transmitting ....................
Page 7
TABLE OF CONTENTS 3.4 Measuring Speed of School of Fish................3-4 3.4.1 Entering a fish mark ..................3-4 3.4.2 Deleting individual fish marks .................3-5 3.5 Relocating School of Fish for Easy Observation ............3-5 3.6 Event Mark, Own Ship Position Mark .................3-6 3.6.1 Event mark .....................3-6 3.6.2 Entering an own ship position mark ...............3-7...
Page 8
TABLE OF CONTENTS APPENDIX 1 MENU TREE ..................AP-1 SPECIFICATIONS .....................SP-1 INDEX.......................... IN-1...
Congratulations on your choice of the FURUNO CSH-5LMARK-2/CSH-8LMARK-2 Color Scan- ning Sonar. Since 1948, FURUNO Electric Company has enjoyed an enviable reputation for innovative and dependable marine electronics equipment. This dedication to excellence is furthered by our ex- tensive global network of agents and dealers.
SYSTEM CONFIGURATION Monitor (MU-150HD, etc., Max. 2) Processor Unit CSH-5210-A Control Unit CSH-5211-A Transceiver Unit CSH-5130-A-5L Navaid Current Indicator AD Converter Speed Log E/S Interface Remote Controller Speaker Motion Sensor MS-100 Hull Unit CSH-5040-A, 600 mm stroke CSH-5041-A, 400 mm stroke Pre-amplifier Unit CSH-5020-A Ship's Mains...
Page 11
SYSTEM CONFIGURATION Processor Unit CSH-5210-A Monitor (MU-150HD, etc., Max. 2) Control Unit CSH-5211-A Transceiver Unit Navaid CSH-8030-A-8L Current Indicator AD Converter Speed Log E/S Interface Remote Controller Speaker Motion Sensor Hull Unit Junction Box MS-100 CSH-8040-A, 600 mm stroke CSH-1700 CSH-8041-A, 400 mm stroke Ship's Mains 100 VAC/...
Page 12
SYSTEM CONFIGURATION This page is intentionally left blank.
OPERATIONAL OVERVIEW Control Unit All operations are carried out from the control unit. All controls quickly respond to the operator's command and the associated reaction can be seen on the screen almost immediately. Lowers the transducer. Trackball Positions trackball Raises the transducer. mark.
1. OPERATIONAL OVERVIEW Remote Controller (option) The remote controller provides armchair control of the tilt, range and gain. Hole for hanging RANGE Control TILT Control ▲: Increases range. ▲: Increases tilt angle. ▼: Decreases range. ▼: Decreases tilt angle. Chooses menu item in menu operation.
1. OPERATIONAL OVERVIEW Basic Operating Procedure 1.3.1 Turning on the power 1. Press the POWER switch on the control unit to turn on the power. 2. Turn on the monitor (user supply). The system initiates the START UP test to check itself for proper operation. The results are shown as OK or NG (No Good).
1. OPERATIONAL OVERVIEW 1.3.3 Transmitting [TRANSMISSION] in the [SONAR] menu is off in the default setting. If it is has been set to [ON], the procedure below is not necessary. When the transducer is lowered, transmission starts and when it is raised transmission is stopped. 1.
1. OPERATIONAL OVERVIEW 1.3.4 Adjusting backlighting of control unit 1. Press the MENU key to open the menu. 2. Use the RANGE control to choose [MENU MODE] at the top of the screen. 3. Use the GAIN control to choose [SYSTEM]. SYSTEM MENU (RANGE CTRL: U/D, GAIN CTRL: L/R) [MENU MODE]...
1. OPERATIONAL OVERVIEW 1.3.5 Choosing a display mode Three display modes are available: NORMAL, COMBI-1 and COMBI-2. To choose the display mode, do the following: 1. Press the MENU key to open the menu. The last-used menu is displayed. 2. Use the RANGE control to choose [MENU MODE] at the top of the screen. 3.
Page 19
1. OPERATIONAL OVERVIEW Normal mode display (sonar display) 12.4 kn SHIP SPEED R 1000 246° ° SHIP COURSE T 15 (15) B 60S LAT/LON G 10.0 32°52.150N 132°12.150E 126m DEPTH WATER CURRENT TO C1 1.2kn 342° Text Window C2 0.8kn 298° For description C3 0.4kn 256°...
1. OPERATIONAL OVERVIEW 1.3.7 Adjusting the gain The GAIN control adjusts receiver sensitivity. It should be adjusted to see fish echoes clearly with minimal noise on the screen. Too high a setting not only causes excessive noise on the screen and makes it difficult to discriminate wanted fish echoes but also causes bottom echoes to be painted in strong colors, resulting that the echoes from bottom fish are masked by bottom reflections.
1. OPERATIONAL OVERVIEW Setting the Tilt Angle The tilt angle shows the direction to which the sound wave is emitted. When the sound wave is emitted horizontally, it is said to be zero (0) degrees and when emitted verti- cally, 90 degrees. To set a tilt angle, operate the TILT lever for the desired angle while watching the tilt angle indication at the top right corner of the sonar display.
1. OPERATIONAL OVERVIEW For example, when the RANGE control, TILT lever and automatic tilt are set to 1000 m, 8° and ±2-10° respectively, the tilt angle changes at each transmission as follows: 8° 10° 8° 6° 8° … Tilt Angle Auto tilt concept 1.4.2...
1. OPERATIONAL OVERVIEW 1.4.3 How to discriminate fish echoes from the bottom The following figure illustrates how two schools of fish (a) and (b) are displayed on screen using three different tilt angles. Case 1: Tilt angle 30 to 40 degrees School of fish is obscured by the bottom echo.
1. OPERATIONAL OVERVIEW sound is reflected just like a light hitting a mirror at a narrow incident angle, it propa- gates away and the sea surface reflections become negligible. However if the sea is not calm enough, they will become dominant and will interfere with observation of wanted echoes.
1. OPERATIONAL OVERVIEW Finding Range and Bearing to a Target Operate the trackball to place the trackball mark on the target you want to measure the range and bearing. The slant range, horizontal range, bearing and depth to the tar- get appear at the upper left corner of the sonar display.
1. OPERATIONAL OVERVIEW Sonar Menu Overview This equipment has four menus: sonar menu, sounder menu, marks menu and system menu. Of the four menus, the [SONAR] menu is the one you will use most often. Note that the gain and range cannot be adjusted while the menu is displayed. 1.6.1 Operating procedure 1.
1. OPERATIONAL OVERVIEW 1.6.2 Sonar menu description Description of sonar menu Item Description Ref. page DISPLAY MODE Chooses the display mode among, [COMBI-1] (NORM + Audio), [NORM] (Sonar) and [COMBI-2] (NORM + Echosounder). TX OUTPUT Adjusts transmitter power. PULSE LENGTH Chooses pulse length. TX CYCLE Removes interference caused by other sonars operat- ing nearby.
Page 29
1. OPERATIONAL OVERVIEW Item Description Ref. page ALARM LEVEL Sets echo strength level which triggers the fish alarm. The lower the setting the weaker the echo which trig- gers the alarm. AUTO TRAIN Turns automatic transducer training on or off. TRAIN SECTOR Chooses train sector in automatic training.
Page 30
1. OPERATIONAL OVERVIEW This page is intentionally left blank. 1-18...
FINE TUNING THE SONAR PIC- TURE Eliminating Unwanted Echoes Echoes from targets such as bottom and fish return to the transducer in order of dis- tance to them, and when we compare their intensities at the transducer face, those from nearer targets are generally stronger when their reflecting properties are nearly equal.
2. FINE TUNING THE SONAR PICTURE proaches. If the color changes suddenly to weaker colors as the fish echo enters FAR and NEAR areas, the TVG is improperly set. Adjust the TVG to correct it. If this again produces sea surface reflections and noise, try to remove them with the AGC and noise limiter as described later on.
2. FINE TUNING THE SONAR PICTURE 2.3.2 Pulse length The pulse length control determines the length of the transmission pulse emitted into the water. While a longer pulse is advantageous for long-range sounding, it has the disadvantage of being poor in discrimination of targets, i.e., ability to separate several closely located targets.
2. FINE TUNING THE SONAR PICTURE Suppressing Bottom and Sea Surface Reflec- tions in Shallow Fishing Grounds In shallow fishing grounds with hard or rocky bottom, bottom reflections often interfere with wanted fish echoes and they can not be eliminated sufficiently with the aforemen- tioned TVG and AGC, especially when the tilt angle is large in order to track schools of fish approaching within 400 m.
2. FINE TUNING THE SONAR PICTURE Rejecting Sonar Interference and Noise While observing the sonar picture, you may encounter occasional or intermittent noise and interference. These are mostly caused by on-board electronic equipment, engine or propeller noise, or electrical noise from other sonars being operated nearby. 2.5.1 Identifying noise source To eliminate noise effectively, you should first identify the noise source.
2. FINE TUNING THE SONAR PICTURE 2.5.4 Rejecting interference with TX cycle When other sonars of the same TX frequency as own sonar are near, an interference ring caused may be displayed. To erase the interference ring from the screen, reduce the TX CYCLE setting.
2. FINE TUNING THE SONAR PICTURE Choosing Beamwidth 2.6.1 Horizontal beamwidth If you wish to have better bearing discrimination (ability to distinguish two closely lo- cated targets at the same range and different bearings) for schools of fish and also wish to examine the contour of bottom, set [HOR BEAMWIDTH] to [NARROW], on the [SONAR] menu.
Page 38
2. FINE TUNING THE SONAR PICTURE This page is intentionally left blank.
ADVANCED SONAR OPERATION Tracking a School of Fish (target lock) Target lock, which requires speed and heading inputs, automatically tracks a fixed lo- cation (such as a reef) so that you won't lose sight of it on the display screen. 1.
3. ADVANCED SONAR OPERATION Detecting Schools of Fish Aurally Sometimes you may be preoccupied with other tasks and unable to concentrate on watching the sonar picture. In such cases it would be a good choice to use the audio function. This function enables you to monitor echoes from schools of fish and bottom through the built-in speaker.
3. ADVANCED SONAR OPERATION The Fish Alarm The fish alarm generates an audio alarm when a fish echo above a certain strength enters the alarm zone. 1. Operate the trackball to place the trackball mark on the starting point of the alarm zone.
3. ADVANCED SONAR OPERATION Measuring Speed of School of Fish To ensure a good haul, it is important to estimate the direction and speed of the school of fish before shooting the net. You can do this with the FISH key. If the tidal current data is used together with fish speed data, you can determine the timing of the net shooting more efficiently.
3. ADVANCED SONAR OPERATION Note 3: Each time the FISH key is pressed the fish mark changes in the sequence shown below. Maximum 10 fish marks may be inscribed, one latest, one 2nd latest and eight past. When this amount is exceeded the oldest fish mark is automatically erased.
3. ADVANCED SONAR OPERATION Event Mark, Own Ship Position Mark 3.6.1 Event mark The event mark, which requires speed and heading data, is useful for finding the hor- izontal range, depth and bearing to a location some distance from current position. Plotting an event mark on the display is equivalent to dropping a buoy with an anchor- ing chain that extends from surface to bottom.
3. ADVANCED SONAR OPERATION Each time the key is pressed the appearance of the event marks changes as be- low. Ten marks may be entered. When this amount is exceeded the oldest event mark is automatically erased. This data is used to display First press of the EVENT key latest event mark data.
3. ADVANCED SONAR OPERATION Function Keys (F1-F4) A function key may be programmed two ways: set up the equipment according to fish- ing ground or target fish, or provide a shortcut for a menu item on the [SONAR] or [SOUNDER] menu. Sonar Menu Item Function Key Default program...
3. ADVANCED SONAR OPERATION 11. Press the MENU key to close the menu. Useful programs (main items only) For detecting surface fish For detecting bottom fish For detecting midwater fish TX OUTPUT TX OUTPUT TX OUTPUT PULSE LENGTH PULSE LENGTH PULSE LENGTH TX CYCLE TX CYCLE...
3. ADVANCED SONAR OPERATION Suppressing Effects of Pitching and Rolling (Stabilizer) The Motion Sensor MS-100 (option) compensates for the affects of pitching and rolling to provide steady, non-fading pictures, along the bearing selected. Follow the proce- dure below to use the stabilizer feature. Tilt angle Stabilizer activated compensated...
ECHOSOUNDER MODE This chapter covers operation of the echosounder picture, which may be displayed by choosing the [COMBI-2] mode. Choosing the Range The basic range and range shifting functions together give you the means to select the depth you can see on the screen. The basic range can be thought of as providing a "window"...
4. ECHOSOUNDER MODE 3. Use the GAIN control to choose [SOUNDER]. SOUNDER MENU (RANGE CTRL: U/D, GAIN CTRL: L/R) [MENU MODE] : SONAR SOUNDER MARKS SYSTEM COLOR RANGE : 160 SHIFT E/S INT REJECT GAIN : 3.0 CLUTTER : 2.0 ADVANCE : 2/1 COLOR CURVE...
4. ECHOSOUNDER MODE Picture Advance Speed The picture advance speed determines how quickly the vertical scan lines run across the screen. When selecting a picture advance speed, keep in mind that a fast advance speed will expand a school of fish horizontally and a slow advance speed will contract Note: Match the picture advance speed to that of the echo sounder.
4. ECHOSOUNDER MODE Suppressing Interference Interference from other sounders or electrical interference shows itself on the screen as in the illustration below. Interference from Inteference from other sounders electrical equipment Interference To remove interference, do the following: 1. Press the MENU key to open the menu. 2.
4. ECHOSOUNDER MODE Erasing Weak Echoes Sediments in the water or reflections from plankton may be painted on the screen in green or light-blue, as shown in the illustration below. These echoes may be erased in order of strength as below. Weak reflections Weak echoes 1.
Page 54
4. ECHOSOUNDER MODE This page is intentionally left blank.
MARKS AND DATA Marks and Data on the Normal Display Freeze condition (for testing) Range (Shown several TX Off Trackball Mark Data Range seconds when range Slant Range Tilt Angle is changed.) Stabilizer Horizontal Range (Auto Tilt value) Depth Heading* Gain B Relative Bearing* Function Key Number...
Page 56
5. MARKS AND DATA Description of marks and data on the normal display Mark/Data Description Own Ship Mark Shows own ship's present position and points in bow direction. When a heading sensor is connected, the north mark is displayed and North Mark* points to north.
Page 57
5. MARKS AND DATA Description of marks and data on the normal display (con't from previous page) Mark/Data Description The range rings are dashed concentric circles inscribed at intervals of Range Rings 1/4 or 1/2 of the range in use, depending on menu setting. Range ring data is also provided every two range rings.
Page 58
5. MARKS AND DATA Description of marks and data on the normal display (con't from previous page) Mark/Data Description This mark depicts important locations. Use the trackball to place the Latest Event Mark trackball mark where desired and press the EVENT key to inscribe an event mark.
5. MARKS AND DATA Marks and Data on the Echosounder and Audio Displays 12.4 kn 126m Speed*, Depth SHIP SPEED DEPTH 246° SHIP COURSE Course* SONAR MARKS AND INDICATIONS SAME AS ON NORMAL DISPLAY 32°52.150N LAT/LON Position* 132°12.150E Range and Bearing Marks 20min WATER TEMP...
Page 60
5. MARKS AND DATA Description of marks and data on the echosounder and audio displays Mark/Data Description Color Bar The color bar provides an estimate of echo strength in 16 colors. The red color is the strongest echo signal. Depth Scale, Range The depth scale and range scale provide an estimate of depth and Scale range in the echosounder and audio displays, respectively.
INTERPRETING THE DISPLAY Bottom Echo When the tilt angle is changed, the bottom echo will appear on the screen. When the tilt angle is decreased, the bottom trace becomes wider and weaker. By observing the bottom condition on the screen, the skipper can prevent the net from being damaged by a reef or a shipwreck.
6. INTERPRETING THE DISPLAY School of Fish A school of fish appears as a mass of echoes. The color of the mass shows the den- sity. To know the distribution and center point of a school of fish, choose several dif- ferent tilt angles.
6. INTERPRETING THE DISPLAY Sea Surface Reflections To reduce sea surface reflections, set the tilt angle to 5° or more so that the upper edge of the sonar beam does not hit sea surface, or adjust the TVG functions. When the sonar is used with a narrow tilt angle, the sea surface reflections cover a large area (up to 300 m to 400 m) as illustrated below.
6. INTERPRETING THE DISPLAY False Echo by Sidelobe An ultrasonic wave is emitted only in the direction set by the TILT lever but, in practice, there are some emissions outside the main beam that are called "sidelobes." Energy of the sidelobe is fairly weak but when the sonar is used in comparatively shallow wa- ter with a hard and rocky bottom, strong target signals are detected by the sidelobe.
MARKS AND SYSTEM MENUS This chapter describes the [MARKS] and [SYSTEM] menus. To display the [SYSTEM] or [MARKS] menu, do the following: 1. Press the MENU key to open the menu. 2. Use the RANGE control to [MENU MODE] at the top of the screen. 3.
Page 66
7. MARKS AND SYSTEM MENUS MARKS menu description Item Description Ref. Page RANGE RINGS Turns the range rings on/off and chooses range ring inter- val, 1/4 or 1/2 the range. When turned off, the north mark and heading mark are also turned off. BEARING SCALE Turns the electronic bearing scale on/off.
7. MARKS AND SYSTEM MENUS SYSTEM Menu SYSTEM MENU (RANGE CTRL: U/D, GAIN CTRL: L/R) [MENU MODE] : SONAR SOUNDER MARKS SYSTEM DIMMER : 10 DISP SELECT TEMP CURRENT HEADING ADJ 0° AUTO RETRACT : OFF (OFF, 5-16kn)OFF SPEED MESSAGE : EXT KP SYNC AUTO TRAIN SPD : HIGH...
Page 68
RATE 4800, 9600 and 19200 (bps). PORT1 FORMAT Sets format of equipment connected to port 1; NMEA or CIF — (Furuno). PORT2 BAUD Sets baud rate of equipment connected to port 2, among 2400, — RATE 4800, 9600 and 19200 (bps).
An activation code is required to set the language to Spanish, Thai, Vietnamese, Bur- mese, or Indonesian. Note: Contact a FURUNO agent or dealer for the password. 1. Select [ACTIVATIONCODE]. 2. Press the EVENT MARK key and below message appears.
Page 70
7. MARKS AND SYSTEM MENUS This page is intentionally left blank.
MAINTENANCE, TROUBLE- SHOOTING NOTICE WARNING o not apply paint, anti-corrosive ELECTRICAL SHOCK HAZARD Do not open the equipment. sealant or contact spray to plastic parts or equipment coating. This equipment uses high voltage that can cause Those items contain products that can electrical shock.
8. MAINTENANCE, TROUBLESHOOTING Hull Unit Maintenance 8.3.1 Lubrication points, zinc plate Replacement of grease cotton Check the grease cotton monthly for water leakage. If leakage is found, tighten the grease cotton retainer. If water continues to Apply MOLYTONE grease #2 (or equivalent) every six months.
8. MAINTENANCE, TROUBLESHOOTING 8.3.2 Manually raising the transducer If the transducer can not be raised automatically, manually raise it as follows: CAUTION CAUTION Turn off the POWER switch on the hull unit before manually raising or lowering the transducer (with the ratchet wrench). Bodily injury may result if the ratchet wrench rotates unexpectedly, because the raise/lower motor may start up.
The processor unit has a fan, and its life is about 25,000 hours, in ambient tempera- ture of 50°C. If the fan stops, because the area around the power supply is too hot, the power volt- age may fluctuate. Contact a FURUNO agent or dealer to request replacement of the fan. Type Code No.
• Debris may be on sea surface. Reject unwanted noise with the interference rejector on the [SONAR] menu. Picture does not • Problem in tilt mechanism or control line. Contact a FURUNO change when tilt agent or dealer for advice.
8. MAINTENANCE, TROUBLESHOOTING Error Messages The table below shows the error messages which may appear on the display. All error messages are accompanied by the audio alarm, which you may silence with the R/B key. Error messages Message Meaning, Remedy Overvoltage OVERVOLTAGE Excessive voltage detected.
8. MAINTENANCE, TROUBLESHOOTING Diagnostic Tests This unit has 10 diagnostic tests (eight with the CSH-8LMARK-2) which check it for proper performance. Although the tests are designed primarily for use by the service technician, they can also be executed by the user to identify defective components. However, never attempt to check inside the unit;...
8. MAINTENANCE, TROUBLESHOOTING 8.8.2 Description of diagnostic tests Single test, Conti(nuous) test The single and conti(nuous) tests check the ROMs and RAMs for proper operation, one time or continuous, respectively. After the test is completed, the results are indicated as OK (normal operation) or NG (malfunction), to the right of the device checked.
Page 79
8. MAINTENANCE, TROUBLESHOOTING Panel test The panel test checks the controls on the control unit for proper operation. 1. Press a key. If the key is normal, "1" is shown at the key's on-screen location when the key is pressed; "0" when it is released. (The POWER switch cannot be checked.) 2.
Page 80
8. MAINTENANCE, TROUBLESHOOTING Color test The color test checks for proper display of colors. Press the EVENT key to change the screen color, in the order of white, blue, green and red. WHITE BLUE GREEN Color test Pattern test The pattern test displays concentric rings overlaid on a grid to test for proper display of rings and horizontal and vertical lines.
Page 81
8. MAINTENANCE, TROUBLESHOOTING Echo tests Test Description Display Echo-1 The echo-1 test checks the echo display function of the monitor for DISPLAY ECHO TEST proper operation, emitting artificial scan signals in 16 colors. If conducted with the COMBI-2 mode active, artificial echoes are shown in the echosounder display to test the ES interface.
Page 82
8. MAINTENANCE, TROUBLESHOOTING This page is intentionally left blank. 8-12...
APPENDIX 1 MENU TREE Default settings shown in bold italics. The menu item [MENU MODE], which chooses a menu, is shown at the top of each menu. Sonar menu MENU key DISPLAY MODE (COMBI-1, NORM, COMBI-2) TX OUTPUT (0-10, 8) (SONAR selected from PULSE LENGTH (0-10, 8)
Page 84
APPENDIX 1 MENU TREE Marks menu MENU key RANGE RINGS (1/4R , 1/2R, OFF) (MARKS BEARING SCALE (ON, OFF) selected from CURRENT VECTOR (ON, OFF) MENU MODE) CURRENT DIR (TO, FROM) SHIP'S TRACK (10R, 5R, OFF) COURSE (32CMPS, 360TRUE) HEADING (32CMPS, 360TRUE, OFF) CURRENT DATA (32CMPS, 360TRUE, ±180°, 360°) EVENT/FISH (32CMPS, 360TRUE, ±180°, 360°) OTHER MARKS (±180°, 360°)
FURUNO CSH-5L/8L MARK-2 SPECIFICATIONS OF COLOR SCANNING SONAR CSH-5L/8L MARK-2 TRANSCEIVER UNIT Transmitter High power MOS FET amplifier with 11-step power reduction switch Receiver Low noise superheterodyne, Continuously scanning beam forming TX frequency CSH-5L MARK-2 55 kHz or 68 kHz...
Page 86
FURUNO CSH-5L/8L MARK-2 Current speed and direction (5 layer) Unit Meter, feet, fathom, P/B Audio search ±10°, ±20°, ±40° and ±60° Features Interference rejecter, Afterglow, Noise limiter, Numeric indication Automatic tilt scanning, over-voltage warning, Unretracted transducer warning HULL UNIT XDCR travel...
INDEX Numerics 2ND AGC ..........2-3 Fan replacement ........8-4 Ffunction keys operating ..........3-8 Activation code.......... 7-5 Fish alarm ..........3-3 AGC ............2-2 FISH ALARM key ........3-3 ALARM ZONE key ........3-3 FISH key ........... 3-4 Audio volume .......... 1-17 FISH marks Auto retraction...........
Page 88
INDEX OFF CENTER key ........3-5 Own ship position mark deleting.............3-7 entering ............3-6 Panel test ...........8-9 Pattern test..........8-10 Picture advance speed (echosounder mode) ........4-3 Ports format ..........7-4 POWER switch ..........1-3 Pulse length ..........2-3 R/B key ............3-2 Range echosounder ..........4-1 sonar ............1-8 RANGE control ..........1-8 Range ring interval ........7-2 Remote controller........1-2...
Page 89
(title and/or number and date of issue of the standard(s) or other normative document(s)) For assessment, see • EMC Test Report FLI 12-02-035, October 4, 2002 prepared by Furuno Labotech International Co., Ltd. • Declaration K-10-18-306, November 16, 2015 prepared by Furuno Electric Co., Ltd.
Page 90
(title and/or number and date of issue of the standard(s) or other normative document(s)) For assessment, see • EMC Test Report FLI 12-02-034 and FLI 12-02-035, October 4, 2002 prepared by Furuno Labotech International Co., Ltd. • Declaration K-10-18-306, November 16, 2015 prepared by Furuno Electric Co., Ltd.
Need help?
Do you have a question about the CHS-5LMARK-2-55 and is the answer not in the manual?
Questions and answers