3. Set the transducer to the soundome, aligning the screw holes.
Note: When the soundome is installed in a low ambient temperature, the soun-
dome may shrink and become difficult to fit to the transducer. To prevent this,
warm the soundome in water of approx. 40°C (104°F) or leave it in room tempera-
ture above 20°C (68°F) for at least one hour.
4. Secure the soundome, using the eight supplied truss head screws (M5 12).
Fastening the screws in diagonal order. Note that the truss head screws do not
require washers.
2
7
3
5 5
1
Note 1: When screw holes on the soundome are not aligned with the screw holes
on the transducer, align the holes as follows:
• When the screw holes are not aligned slightly:
Insert a screwdriver in holes to align them.
• When the screw holes are totally out of alignment:
Detach the soundome as follows and then reattach it.
1) Orient the soundome vertically.
40°C
6
4
8 8
Truss head screw
1. MOUNTING
1-25