Furuno CH-500 Installation Manual page 52

Dual-frequencysearchlight sonar
Hide thumbs Also See for CH-500:
Table of Contents

Advertisement

2. WIRING
No.
Cable
4
FRU-CCCAF-18-05/10M-B
5
FRU-NMEA-PMM-01
6
MJ-A10SPF0022-050+/100+
7
FRU-WH-B-05/10M
8
FRU-WH-A-15/30/50M
9
DPYCY-2.5*
10
Ground Wire (IV-2sq.)
*: Fabricate the power cable (DPYCY-2.5, supplied locally), referring to the following
figure.
Fabrication of DPYCY-2.5 cable
Armor
Vinyl tape
Clamp with the cable fixing plate.
External KP connection
To synchronize the KP (Keying Pulse) signal from the external equipment, make the
connection as follows. Also, change the DIP switch (S8-3) on the DIGI board
06P0288, according to the logic signal of the external equipment.
DIGI board
06P0288
2-6
DIGI board 06P0288:
POWER port (J112) and
CONT port (J111)
DIGI board 06P0288: J118
DIGI board 06P0288: J115
DIGI board 06P0288: J124
DIGI board 06P0288: J114
ANLG board 06P0289: J105
and J106
ANLG board 06P0289: TB101 Ship's main (12-24 V DC)
Ground terminal
40 mm
40 mm
Inner sheath
KP input signal setting
DIP SW S8-3
3.3 V
ON: Negative
OFF: Positive
10 kΩ
5 kΩ 2.4 V
AUX_SIG_OUT_LF (no use) > 4 >
10 kΩ
AUX_SIG_OUT_HF (no use) > 7 >
GND
Access point on the
transceiver unit
100
100
60 mm
60 mm
10 mm
Attach the supplied crimp-on lug (FV2-4
BLU) to the cores.
J124
12V_P > 1 >
KP_OUT > 2 >
KP_IN > 3 >
EXT_SW (no use) > 5 >
GND > 6 >
FRU-WH-B-5M/10M
Cable from
Display unit
Navigation equipment
(NMEA2000)
No.2 control unit
External KP
Hull unit
Ship's ground
KP
5 to 12.6 V
Blue
External
equipment
Orange