Furuno CH-500 Installation Manual page 65

Dual-frequencysearchlight sonar
Hide thumbs Also See for CH-500:
Table of Contents

Advertisement

1. Measure the roll and pitch angles of the two locations shown in the following fig-
ure, using a angle meter. When the raise/lower control unit is not separated from
the hull unit, go to next step.
Measure the roll and pitch
angles of these locations.
Hull unit
2. Press the MENU key to open the menu.
3. Press
on the cursorpad to select [COM2] on the menu bar.
4. Press
to move the cursor inside the menu.
Menu
COM1
COM2
HOR.
Delete Track
No
White Marker
Off
Erase Color
Off
Echo Colors
32
BKGD. Colors
3
Bearing
Relative
Heading
+0
Roll Offset
+0.0
Pitch Offset
+0.0
Sensor Correct
+0
Delete sonar track.
: Select
: Change
Menu: Apply
For CH-500
5. Press
several times to select [Roll Offset]. When the raise/lower control unit is
not separated from the hull unit, go to step 11
6. Press
to open the setting window.
Roll Offset
Detect Val : - -
7. Press
or
to adjust the offset value.
Calculate the offset value for [Roll Offset], using the values measured at step 1.
• [Roll Offset] = "Hull unit's roll angle" minus "Raise/Lower control unit's roll an-
gle"
8. Press
to select [Pitch Offset].
Reference direction
Disable transducer 
raise/lower function
Raise/lower control unit
VERT
ES
FUNC Key
System
+0.0°
(-10.0~+10.0 ° )
Compensated value
appears here.
3. CHECKING AND INITIAL SETTINGS
Roll Offset
ON
POWER
+
OFF
+
Sensor Correct
Menu
COM1
COM2
HOR.
VERT
Delete Track
No
Mix Mode
Compress
White Marker
Off
Erase Color
Off
Echo Colors
32
BKGD. Colors
3
Bearing
Relative
Heading
+0
Roll Offset
+0.0
Pitch Offset
+0.0
Sensor Correct
+0
Delete sonar track.
: Select
: Change
Menu: Apply
For CH-600
- +
Pitch Offset
-
-
Bow
ES
FUNC Key
System
3-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ch-600

Table of Contents