Feldbus gateway – profinet-io
Table of Contents

Advertisement

Specifications for Leuze end devices
KONTURflex specifications
Settings on the MA
• PROFINET address is freely selectable
• Device selection switch at position "0"
PROFINET settings
• Module selection:
Dependent on number of beams used, but at least "8 bytes In"
• User parameters:
"Transparent mode", "Use GSD settings", baud rate 38400, "8 data bits",
"No parity", "2 stop bits"
KONTURflex settings
First, the following settings are to be performed on the device using KONTURFlex-Soft:
• Either "Autosend (fast)" or "Autosend with data in Modbus format"
• Repeat time "31.5ms"
• Autosend baud rate "38.4KB"
• 2 stop bits, no parity