In order to communicate with the connected Leuze device, the STX, data, CR, LF framing
must be set on the PC terminal program, as the Leuze device is preconfigured ex works for
this frame character.
STX (02h):
CR (0Dh):
LF (0Ah):
Operation
 Switch the MA
The Leuze device is now connected to the fieldbus. Activation of the Leuze device can now
occur via the switching input on the MA 248i, via the process data word Out bit 1 (bit 0.2)
or by transmitting a "+" command to the Leuze device (see chapter 16 "Specifications for
Leuze end devices"). For further information on the fieldbus transmission protocol, see see
chapter 10 "Telegram".
Reading out information in service mode
 Set the service switch of the gateway to switch position "MA" (gateway).
 Send a "v" command to call up all service information of the MA 248i.
An overview of the available commands and information can be found in chapter "Reading
out information in Service mode" on page 45.
12.6.1 Specific feature for the use of hand-held scanners
(bar code and 2D devices, combi devices with RFID)
Notice!
For a description of device configuration and the required codes, please see the correspond-
ing documentation at www.leuze.com.
12.6.1.1 Cable-connected hand-held scanners on the MA
All hand-held scanners and mobile combi devices available in the Leuze electronic product
line can be used with the corresponding connection cable.
When using the MA 248i, the voltage supply of the hand-held scanner (5V/at 1A) can be
connected to the interface by means of a cable via the 9-pin Sub-D connector (voltage on
PIN 9). The corresponding cable is to be selected for the respective hand-held scanner and
ordered separately. The 9-pin Sub-D cable (KB JST-HS-300, part no. 50113397) is
connected to this cable, which is connected to the MA 248i. This cable must also be ordered
separately.
In this example, triggering occurs by means of a trigger button on the hand-held scanner.
Leuze electronic
Prefix 1
Postfix 1
Postfix 2
248i
to switch position "RUN" (operation).
MA
Commissioning and configuration
248i
248i