Configuration; Configuration Of The Modules - Leuze electronic MA 248i Original Operating Instructions

Feldbus gateway – profinet-io
Table of Contents

Advertisement

Fast commissioning / operating principle
3.5.3

Configuration

 Configure the PROFINET-IO system with the HW Config of the SIMATIC Manager by
inserting the MA
Figure 3.2:
Here, an IP address is assigned to a unique "device name".
3.5.4

Configuration of the modules

 Now select a corresponding data module for the input and output area.
A number of different modules are available with various data lengths (4, 8, 12, 16,
20, 32 ... 1024 bytes).
Notice!
Because the data module contains 2 bytes for the control and status bytes, the actual user
data length is always 2 bytes smaller than the selected data module.
E.g., when using the data module with 12 bytes, there are effectively 10 bytes available for
user data on the Leuze device after subtracting the 2 bytes for status and control bytes.
14
248i
into your project.
Assignment of the device names to IP addresses
MA
248i
Leuze electronic