Mounting
6.2

Mounting the E-Stop Rope Switch

Prerequisites for mounting:
• actuator head has been set
Select the mounting locations so that the following conditions are satisfied:
• maximum rope length is not exceeded (see figure 6.2)
• E-Stop Rope Switch is not subject to any physical shocks or vibrations
• rope can be easily accessed by operating personnel in the entire operating
area
• pulling the rope in any direction triggers an E-Stop
• the occupied area is visible along the entire rope length from the location of
the E-Stop Rope Switch
• rope is aligned with the axis of the E-Stop Rope Switch button (if applicable,
to the first deflection roller)
Position the E-Stop Rope Switch button so that it is aligned with the direction
of the rope.
Position the washers and screw down the E-Stop Rope Switch with 2–3 Nm.
Secure stud bolt or support for rope clamp with eyelet.
If necessary, mount deflection rollers.
If necessary, mount eye bolts as rope guides at intervals of 2–3 m.