VWR INCU-Line Series Instruction Manual

VWR INCU-Line Series Instruction Manual

Peltier cooled incubators

Advertisement

®
VWR
INCU-Line
Peltier Cooled Incubators
Instruction Manual
European Catalogue Numbers:
INCU-Line IL 56PR: 390-1031
INCU-Line IL 112PR: 390-1032
INCU-Line IL 240PR: 390-1033
Before using the equipment, please read
this instruction manual carefully!
Version 1.0
Issued 01.01.2018

Advertisement

Table of Contents
loading

Summary of Contents for VWR INCU-Line Series

  • Page 1 ® INCU-Line Peltier Cooled Incubators Instruction Manual European Catalogue Numbers: INCU-Line IL 56PR: 390-1031 INCU-Line IL 112PR: 390-1032 INCU-Line IL 240PR: 390-1033 Before using the equipment, please read this instruction manual carefully! Version 1.0 Issued 01.01.2018...
  • Page 2 Instruction Manual INCU-Line Peltier Cooled Legal Adress of Manufacturer: Country of Origin: Poland Page 2 / 33...
  • Page 3 Instruction Manual INCU-Line Peltier Cooled Page 3 / 33...
  • Page 4 Instruction Manual INCU-Line Peltier Cooled Page 4 / 33...
  • Page 5: Table Of Contents

    Instruction Manual INCU-Line Peltier Cooled Contents 1 IMPORTANT INFORMATION FOR THE USER ....................7 2 PACKAGE CONTENTS ............................. 8 3 BEFORE THE FIRST USE ..........................8 3.1 Shelf installation ................................9 3.2 Condensation in the chamber ............................. 10 3.3 Placement of samples ..............................10 3.4 Closing the chamber door ............................
  • Page 6 Instruction Manual INCU-Line Peltier Cooled 11.1 Possible defects ............................... 29 11.2 Circuit breaker ................................30 12 WARRANTY CONDITIONS ........................... 30 13 PRODUCT IDENTIFICATION LABEL ......................31 14 TECHNICAL DATA ............................32 Page 6 / 33...
  • Page 7: Important Information For The User

    Instruction Manual INCU-Line Peltier Cooled 1 IMPORTANT INFORMATION FOR THE USER To guarantee your security and the longevity of the unit, please comply with the following rules: The unit cannot be installed: • outside, • in damp places or places which can be easily flooded, •...
  • Page 8: Package Contents

    Instruction Manual INCU-Line Peltier Cooled 2 PACKAGE CONTENTS INCU-Line devices are delivered with the following equipment: INCU-Line IL 56PR, 2 stainless steel wire shelves with set of slides – 2 pcs each, keys to the lock (2 pcs), Manufacturer test certificate at 37 C, Multilingual instruction manual on CD.
  • Page 9: Shelf Installation

    Instruction Manual INCU-Line Peltier Cooled • Not designed to be built-in e.g. within a wall cavity • Placed near a mains socket 230V/50Hz. Non-compliance with the above recommendations may result in damage to the unit or impair tech- nical parameters. The unit has been equipped with levelling feet.
  • Page 10: Condensation In The Chamber

    Instruction Manual INCU-Line Peltier Cooled 1. Install the slides at the selected height by inserting it into appropriate slots on the chamber wall. 2. Insert the second slide bracket into appropriate slots on the opposite side of the chamber wall. 3.
  • Page 11: Closing The Chamber Door

    Instruction Manual INCU-Line Peltier Cooled The picture below is an example of the placement of samples in the chamber. Front view Shelf Hmax = 2/3H Top view u+v+w > 1/3 a x+y+z > 1/3 b ≅ ≅ u v w ≅...
  • Page 12: Description Of The Unit

    Instruction Manual INCU-Line Peltier Cooled 4 DESCRIPTION OF THE UNIT (1) Nameplate (2) USB port (3) Access port (30 mm) (4) Internal glass door (5) Height adjustable feet (6) Shelf (7) Door (8) Key lock (9) Slide (10) Chamber fans (11) Open door sensor (12) Main power switch (13) Electronic controller with touch panel...
  • Page 13 Instruction Manual INCU-Line Peltier Cooled (14) Interface LAN (for service only) (15) Main power socket (16) Fuse Page 13 / 33...
  • Page 14: Control Panel

    Instruction Manual INCU-Line Peltier Cooled 4.1 Control panel – setup (for more information, see point 5.5) – current temperature – set temperature, to change, press the icon or value (for more information, see point 5.2) – alarm bar – if an alarm occurs, the bar is red (for more information, see point 5.5) –...
  • Page 15: Device Operation

    Instruction Manual INCU-Line Peltier Cooled 5 DEVICE OPERATION 5.1 Start, stop and edit the program the program is stopped. Press to open the window where is possible to enter program parameters: • Temperature – set temperature (can’t be lower than under temperature protection +2 C and higher than over temperature protection -2 •...
  • Page 16: Quick Change Of The Parameters

    Instruction Manual INCU-Line Peltier Cooled - the program is running. Press button to stop the program. It is necessary to confirm: 5.2 Quick change of the parameters To change set temperature or set time without stopping the program, press the icon: –...
  • Page 17: Alarm Bar

    Instruction Manual INCU-Line Peltier Cooled To change the type of displayed time, press (in this window): - to display elapsed time, - to display remaining time. 5.3 Alarm bar The colour of the bar indicates the status of the device: –...
  • Page 18: Status - Description

    Instruction Manual INCU-Line Peltier Cooled 5.4.2 Status - description The status of the device is indicated by description. 5.4.3 Alarms In this place appears the list of alarms. With active alarm, the control bar is red. The alarm event is displayed in the list, with the status alarm active.
  • Page 19: Setup

    Instruction Manual INCU-Line Peltier Cooled 5.5 Setup Available when you press the button 5.5.1 Data record Data record contains recorded temperature values with data and time. Data recording interval is 1 minute. The maximum amount of data that can be saved is 10 000. Results are displayed chronologically from new- est to oldest.
  • Page 20: Event Log

    Instruction Manual INCU-Line Peltier Cooled You are able to sort the selected column by clicking its heading. To refresh data To save data on USB-stick To delete data 5.5.2 Event log The window contains information about events, alarms, and errors that have been registered. The following messages may be displayed: Program Start –...
  • Page 21: Statistics

    Instruction Manual INCU-Line Peltier Cooled 5.5.3 Statistics This window displays the statistics of the currently executed or completed program. Statistics are not available if the program is running but has not yet reached the set temperature (status: ramp). Program time countdown starts set point +/-0,5 C.
  • Page 22: Info

    Instruction Manual INCU-Line Peltier Cooled – to change date, – to change time, – to change time zone, – change of time after which the backlight is off. Date and time cannot be changed while the program is running. If you change the date and time to an earlier than the current one, a message will appear on the display: Changing the date/time will interfere with the records in the database.
  • Page 23: Door Lock

    Instruction Manual INCU-Line Peltier Cooled 6.2 Door lock All ILPR units have been equipped with a door lock located in the door handle. Two keys are attached on the backside of the device. 6.3 Access port Ø 30 mm access port can be used to insert an external temperature sensor, which has been secured with a silicon plug.
  • Page 24: Internal Led Light

    Instruction Manual INCU-Line Peltier Cooled Open door sensor 6.5 Internal LED light Internal lighting is switched on automatically when the outside door is open. Once the light has been switch on, a bulb icon will appear on the display. 6.6 USB port To transfer data from the unit’s memory to the USB memory stick, connect the memory stick to the USB slot on the device.
  • Page 25: Lan

    Instruction Manual INCU-Line Peltier Cooled Data saved as *.csv file can be opened in the Notepad. Data saved as *.plkx file can be opened only by Basic Software for ILPR. This program allows you f. ex. to view the data in the table as a graph. It allows you to make a report of selected data range.
  • Page 26: Temperature Protection

    Instruction Manual INCU-Line Peltier Cooled 7 TEMPERATURE PROTECTION Temperature protection is included as standard, if damage occurs to the temperature controller or the user changes the temperature settings outside of the upper and lower limits, temperature protection will activate. Protection class 3.3 is a standard. The figure below shows how this works. Protection Class 3.3.
  • Page 27: Cleaning And Maintenance Of The Device

    Instruction Manual INCU-Line Peltier Cooled 9 CLEANING AND MAINTENANCE OF THE DEVICE Before cleaning the device, it needs to be disconnected from the electrical supply! Maintenance (cleaning of the housing and the chamber) should be carried out at least once a week (depending on the environmental conditions in the workplace).
  • Page 28: Interior Cleaning

    • Complete technical service contact information • Access to VWR’s Online Catalogue, and information about accessories and related products • Additional product information and special offers Contact us for information or technical assistance contact your local VWR representative or visit www.vwr.com Page 28 / 33...
  • Page 29: Possible Defects

    The unit is not heating Check if the door of the unit is closed properly Clean the gasket Check if the fan is turned on If not please contact VWR service Does the installation site meet the installation Adapt to the installation re-...
  • Page 30: Circuit Breaker

    VWR International warrants that this product will be free from defects in material and workmanship for a pe- riod of two (2) years from date of delivery. If a defect is present, VWR will, at its option and cost, repair, re- place, or refund the purchase price of this product to the customer, provided it is returned during the warranty period.
  • Page 31: Product Identification Label

    The customer is responsible for applying for and obtaining the necessary regulatory approvals or other au- thorizations necessary to run or use the Product in its local environment. VWR will not be held liable for any related omission or for not obtaining the required approval or authorization, unless any refusal is due to a defect of the product.
  • Page 32: Technical Data

    Instruction Manual INCU-Line Peltier Cooled 14 TECHNICAL DATA INCU-Line 56PR INCU-Line 112PR INCU-Line 240PR air convection forced chamber capacity door type solid + internal glass door temperature range [º 0...+70 (max 20 C below ambient temp.) temperature variation (spatial) at 37 +/- 0,2 +/- 0,2 +/- 0,3...
  • Page 33 Instruction Manual INCU-Line Peltier Cooled Page 33 / 33...

This manual is also suitable for:

Incu-line il 56prIncu-line il 112prIncu-line il 240pr

Table of Contents