Temporal Zone Codes (Z1 through Z6)
8346-003-115-B
Issue 1, August 1999
The Compact Dialer will be able to route calls based on the internal clock maintained by
the Dialer's internal processor. The clock is not powered by a battery but is powered
while the Dialer is connected to an Exchange line or to an external power source. A loss
of both sources will require that the clock be re-programmed with the correct time and
date.
There are six temporal zones, which can be programmed into Registers 60 through 65.
At the start of each call, the Dialer will examine each register and compare it to the current
time of day and day of week to determine which zone is currently in effect. Once a match
is made, all succeeding registers will be ignored. If temporal zone routing is not in effect,
a Search Table match will execute the normal route action. If temporal zone routing is in
effect, a Search Table match will result with the Dialer routing the call to the route
specified for the selected time zone. If this value is 0, the routing action will follow the
normal route.