    These instructions are a part of the device and must thus always be kept in the direct vicinity of the mounting site or on the device itself. Made by REMKO This operating manual is a translation of the German original, Version W-08...
  • Page 4: Safety Notices

    REMKO DZH Safety Notices Device Description When using the appliance, always observe the respective local construc- The unit is a mobile heater and is tion and fire protection ordinances as well as the regulations of the directly fueled with EL heating oil employers‘...
  • Page 5: Mounting Regulations

    Mounting Regulations Sequence of functions When the unit is in use, the safety Mounting in closed, guidelines of the employers‘ liability well-ventilated rooms After the unit has been switched on insurance associations, the respective or in case heating is reqired (auto- country construction ordinances, and According to the type, the unit ■...
  • Page 6: Commissioning

    An optional tank heater is 2. Switch the must be shut down immedi- ately and the supervisor must available as a REMKO accessory. operating switch to the be informed! „I“ position (on). Fill the fuel container with clean ■...
  • Page 7: Shutdown

    Shutdown Notices regarding the safety Heating with room thermos- 1. Switch the operating cut-off of the unit tat (accessory) switch to the „0“ position (off). The unit fuel supply takes place in The appliances operate fully auto- a single line system. matically depending on the room In this regard, the fuel supply to temperature.
  • Page 8: Maintenance And Care

    REMKO DZH Maintenance and Care Parameters of initiating elec- The regular care and observance of Clean the tank filter in the filler ■ trodes and air slide valve some basic prerequisites guarantee neck of the fuel tank regularly. malfunction-free operation and a long service life of the unit.
  • Page 9: Trouble Shooting

    Trouble Shooting Faults: Cause: The supply air fan does not actuate. 2 – 3 – 4 – 6 – 7 – 8 – 25 The fan is running, but the burner does not ignite. 1 – 5 – 6 – 9 – 10 – 11 – 12 – 13 – 14 – 15 – 16 – 17 Das Gerät geht ohne Flammbildung auf Störung.
  • Page 10: Exploded View Dzh

    REMKO DZH Exploded view DZH 20-2 We reserve the right to make changes in dimensions and design in the interest of technical advances.
  • Page 11 Spare parts list Designation EDP-No. Designation EDP-No. Combustion chamber, complete 1111660 Mounting plate 1111675 Transport grip 1103903 1107134 Inspection cover 1111661 Photoelectric cell mount 1111676 Hose clamp 1103762 Photoelectric cell 1108209 Fuel filter (disposable) 1102146 Ignition cable with plug 1107137 Intake guard grille 1111662 Ignition electrode...
  • Page 12: Exploded View Dzh

    REMKO DZH Exploded view DZH 30-2/50-2 We reserve the right to make changes in dimensions and design in the interest of technical advances.
  • Page 13: Spare Parts List Dzh

    Spare parts list Designation DZH 30-2 DZH 50-2 Designation DZH 30-2 DZH 50-2 EDP-No. EDP-No. EDP-No. EDP-No. 01 Combustion chamber, cpl. 1111690 1111705 40 Nozzle 1107126 1111717 02 Inspection cover 1111691 1111706 41 Nozzle cradle 1107132 1107132 05 Intake guard grille 1111692 1111707 42 Mounting plate 1111675 1111675...
  • Page 14: Exploded View Dzh 90

    REMKO DZH Exploded view DZH 90 53 54 55 55 61 56 54 15 16 16 8 71 56 77 78 80 82 83 84 We reserve the right to make changes in dimensions and design in the interest of technical advances.
  • Page 15: Spare Parts List Dzh

    Spare parts list Designation EDP no. Designation EDP no. Cover 1107350 Lower cover 1107370 Inspection cover 1107351 1107371 Combustion chamber cpl. 1107352 Re-cooling thermostat 1107182 Temperature limiter (STB) 1107353 Swivel disc 1103743 Air inlet plate 1107354 Nozzle 1107372 Solenoid coil 1103766 Nozzle mounting 1103745...
  • Page 16: Proper Use

    „Warranty Document“ inclu- material, think of the environment. mercial use (no private living area ded in delivery to REMKO GmbH Our equipment is carefully packed heating). & Co. KG at the time of the sale...
  • Page 17: Electrical Wiring Diagram

    Electrical wiring diagram Legend: = Operating switch NK = Re-cooling thermostat = Condenser = Relay socket = Photoelecrtic cell = Thermostat plug socket HS = Auxiliary relay STB = Safety limiter = Motor = Ignition electrode MV = Solenoid valve = Ignition transformer We reserve the right to make changes in dimensions and design in the interest of technical advances.
  • Page 18: Maintenance Log

    REMKO DZH ✍ Maintenance log Model ........Model No........10 11 12 13 14 15 16 17 18 19 20 Clean unit – surface – Clean unit – interior – Clean fan blade Clean fan housing Clean condenser Clean evaporator Fan function checked Intake grille with filter cleaned...
  • Page 19: Technical Data

    Technical Data Device type DZH 20-2 DZH 30-2 DZH 50-2 DZH 90 Nominal heating capacity Air capacity 1400 1800 Fuel EL heating oil according to DIN 51603 or diesel fuel Max. fuel consumption 2,01 3,62 4,62 9,38 Nozzle (Danfoss) 0,40/80°S 0,60/80°S 0,85/80°S 1,75/80°S...