These instructions are a part of the device and must thus always be kept in the direct vicinity of the mounting site or on the device itself. Made by REMKO This operating manual is a translation of the German original, Version W-08...
REMKO DZH Safety Notices Device Description When using the appliance, always observe the respective local construc- The unit is a mobile heater and is tion and fire protection ordinances as well as the regulations of the directly fueled with EL heating oil employers‘...
Mounting Regulations Sequence of functions When the unit is in use, the safety Mounting in closed, guidelines of the employers‘ liability well-ventilated rooms After the unit has been switched on insurance associations, the respective or in case heating is reqired (auto- country construction ordinances, and According to the type, the unit ■...
An optional tank heater is 2. Switch the must be shut down immedi- ately and the supervisor must available as a REMKO accessory. operating switch to the be informed! „I“ position (on). Fill the fuel container with clean ■...
Shutdown Notices regarding the safety Heating with room thermos- 1. Switch the operating cut-off of the unit tat (accessory) switch to the „0“ position (off). The unit fuel supply takes place in The appliances operate fully auto- a single line system. matically depending on the room In this regard, the fuel supply to temperature.
REMKO DZH Maintenance and Care Parameters of initiating elec- The regular care and observance of Clean the tank filter in the filler ■ trodes and air slide valve some basic prerequisites guarantee neck of the fuel tank regularly. malfunction-free operation and a long service life of the unit.
Trouble Shooting Faults: Cause: The supply air fan does not actuate. 2 – 3 – 4 – 6 – 7 – 8 – 25 The fan is running, but the burner does not ignite. 1 – 5 – 6 – 9 – 10 – 11 – 12 – 13 – 14 – 15 – 16 – 17 Das Gerät geht ohne Flammbildung auf Störung.
REMKO DZH Exploded view DZH 90 53 54 55 55 61 56 54 15 16 16 8 71 56 77 78 80 82 83 84 We reserve the right to make changes in dimensions and design in the interest of technical advances.
„Warranty Document“ inclu- material, think of the environment. mercial use (no private living area ded in delivery to REMKO GmbH Our equipment is carefully packed heating). & Co. KG at the time of the sale...
Electrical wiring diagram Legend: = Operating switch NK = Re-cooling thermostat = Condenser = Relay socket = Photoelecrtic cell = Thermostat plug socket HS = Auxiliary relay STB = Safety limiter = Motor = Ignition electrode MV = Solenoid valve = Ignition transformer We reserve the right to make changes in dimensions and design in the interest of technical advances.
Customer Care is on the job. REMKO Our extensive network of experienced dealers guarantees you constant, short- term, and reliable service. REMKO GmbH & Co. KG Air conditioning and heating technology Im Seelenkamp 12 D-32791 Lage Postfach 1827 D-32777 Lage...