5.1.3 General Read Page of MPT

The following sequence of bytes reads page 2 of an MPT.
Content
Byte
(hex)
0
01
1
04
2
48
3
32
4
01
5
08
6
77
5.1.4 Program Page of MPT
The following sequence of bytes programs page 2 of an MPT with:
00
00
00
MSByte
Content
Byte
(hex)
0
01
1
0F
2
6C
3
32
4
0F
5
0B
6
09
7
47
8
C6
9
2D
10
00
11
00
12
00
13
00
14
00
15
96
16
50
17
36
SCBU027 – May 2000
Submit Documentation Feedback
Comment
Start Mark
Length
Four bytes follow excluding BCC
Command Field (1)
Perform Single command, send Power Burst I with data
Data Field (1)
Power Burst I with 50 ms duration (charge-up)
Data Field (2)
One Data Field follows
Data Field (3)
Write Address specifying General Read Page 2
BCC
BCC over previous bytes excluding Start Mark
00
00
2D
C6
LSByte
Comment
Start Mark
Length
15 bytes follow excluding BCC
Command Field (1)
Perform Single command, calculate FBCC, send Power Burst I & II with Data
Data Field (1)
Power Burst I with 50 ms duration (charge-up)
Data Field (2)
Power Burst II with 15 ms duration (Progr. burst)
Data Field (3)
11 Data Fields follow
Data Field (4)
Write Address specifying Program Page 2
Data Field (5)
Programming data (LSByte)
Data Field (6)
Programming data
Data Field (7)
Programming data
Data Field (8)
Programming data
Data Field (9)
Programming data
Data Field (10)
Programming data
Data Field (11)
Programming data
Data Field (12)
Programming data (MSByte)
Data Field (13)
DBCC (LSByte)
Data Field (14)
DBCC (MSByte)
BCC
BCC over previous bytes excluding Start Mark
Description
47
Description
Communication Protocol Examples
PC to Micro-reader
35