Instruction List - UIrobot UIM2842 User Manual

Can2.0b instruction control, miniature integrated stepper motor controller (closed-loop) v1.0
Table of Contents

Advertisement

UIM2842
note encoder interface is a standard module which is available as long as Sensor Input
Module is installed.
Enable Closed-loop Control Module
The Encoder-based Closed-loop Control Module (hereinafter referred to as Closed-loop
Control Module) is enabled by configuring the QEM bit of MCFG (MCFG<11>). When
MCFG<QEM>=0, this module is disabled; when MCFG<QEI>=1, it is enabled.
Please note, closed-loop control module is a must even if user uses external encoders.
Otherwise, UIM2842 controller can only read the external encoder data, but cannot
maintain closed-loop motion control with this data. However, if the internal encoder is
installed, Closed-loop Control Module is automatically included.
For master configuration register (MCFG), please refer to Section 5.4.

Instruction List

9.2
The following table shows the instructions mentioned in this chapter, the detail of those
instructions is descriped at the end of the document.
Instruction Description
QECη;
QEC;
QERη;
QER;
SQTη;
Page 54
Set desired quadrature encoder's position η
Check current quadrature encoder's position
Set quadrature encoder's resolution η
Check quadrature encoder's resolution
Set tolerance η of blocked alarm
M4220170607EN
Page
90
91
92
93
100
UI Robot Technology Co. Ltd.