Convection-Oven Blower Does Not Run, Continued
DISCONNECT POWER AT CIRCUIT BREAKER.
Check all wiring for loose terminals or breaks.
A
G
DJUSTMENT OF
AS
The pressure regulator is factory set at 4" W.C. (0.99 kPa) for natural gas and 10" W.C. (2.48 kPa) for propane gas.
To check the manifold pressure:
1. Turn all thermostats and burner control knobs to OFF position.
2. Turn main gas valve to entire range off.
3. Remove control panel and locate the small plug in the manifold.
4. Remove plug and install a fitting appropriate to connect a manometer.
5. Turn on main gas to range and light pilots.
6. Turn all burners and ovens to full ON position and read manometer.
7. If manometer does not read 4" W.C. (0.99 kPa) for natural gas, or 10" W.C. (2.48 kPa) for propane gas, adjust
regulator (if gas pressure is correct go to Step 10).
8. Remove cap from top of regulator.
9. With a screwdriver rotate regulator adjustment screw clockwise to increase, or counterclockwise to decrease,
pressure until manometer shows correct reading.
10. Repeat steps 1 and 2.
11. Remove manometer fitting and replace plug in manifold.
12. Turn on main gas to range and light pilots.
13. Replace control panel.
O
'
WNER
S
(Continuing from previous page.)
CHECK THAT POWER IS DISCONNECTED
AT CIRCUIT BREAKER.
Remove the wire terminal cover from the blower motor.
Check that the red wire is capped off.
Remove the wire nuts from the black and the white wires. Check
that in each case the wires are twisted together securely.
Check that the common wire is connected to the motor black wire.
Check that the neutral wire is connected to the white wire.
Reconnect the power supply and turn on blower-control switch.
Use a voltmeter to measure the voltage between the black wire and
No
P
R
RESSURE
EGULATOR
M
1191904 REV 1 (11/10)
ANUAL
the white wire.
Is there voltage?
DISCONNECT POWER AT CIRCUIT BREAKER.
Remove the wire nuts from the red, white, and black wires.
Check that the resistance across the white and black wires is
approximately 1.9 ohms. Check that the resistance across the
white and red wires is also approximately 1.9 ohms. If either
resistance is incorrect, replace the blower motor.