6
6.4
6.4.1
6.4.1
Wiring according to EMC (installation of a CE-typical drive system)
6.4-2
Wiring according to EMC (installation of a CE-typical drive system)
Drives comply with the EMC Directive if they are installed according to the
guidelines for CE-typical drive systems.
compliance of his application with the EC directives.
) ) ) )
Note!
Control cables and mains cables must be separated from the
l
motor cable to avoid interferences.
Control cable must always be shielded.
l
We recommend to shield the supply cable for the PTC or
l
thermal contact and route it separately from the motor cable.
If the cores for motor connection and PTC or thermal contact
l
are together in one cable with a common shield:
– In order to reduce interference injections on the PTC cable,
we recommend to install additionally the PTC module type
E82ZPEx.
An optimum HF shield connection of the motor cable can be
l
reached by using the terminal
shield.
EDS82EV903-1.0-11/2002
Basic unit wiring
Basic units in the power range 0.25 ... 2.2 kW
The user is responsible for the
2
for motor PE and motor
L