Changing Faceplate - Siemens SIMATIC NET RUGGEDCOM RSG2100 Service Manual

Industrial ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG2100:
Table of Contents

Advertisement

Module Replacement
2.3.1 Changing Faceplate
6.
7.
8.
2.3.1

Changing Faceplate

If the new module is not the same as the previous one, the faceplate must be re-
placed.
To change the faceplate for the module, do the following:
1.
2.
3.
4.
26
Apply the product label included in the in-field modification kit to the device.
Install the updated factory file included in the in-field modification kit.
For more information, refer to the instructions included in the kit.
Return the device to service.
Remove the three Philip head screws that secure the current faceplate to the
main inner asembly.
1
2
Faceplate
1
Screw
2
Figure 2.19
Removing the Faceplate
Remove the faceplate.
Align the new faceplate (included in the module kit) on the main inner assem-
bly.
Secure the faceplate to the main inner assembly using three Philip head screws.