Accessing Modules On The Bottom Row - Siemens SIMATIC NET RUGGEDCOM RSG2100 Service Manual

Industrial ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG2100:
Table of Contents

Advertisement

8.
2.2.2

Accessing Modules on the Bottom Row

If the module you want to replace is in slot 2, 4, 6, 8, or 10 along the bottom row,
the main inner assembly needs to be partially removed to gain access.
To partially remove the main inner assembly, do the following:
NOTICE
Environmental hazard – risk of damage to the device
Protect modules, connectors, and wiring from dirt, heat, static electricity, and mois-
ture. Have connector covers available and wear appropriate ESD protective equip-
ment.
1.
RUGGEDCOM RSG2100
Service Manual, 07/2019, C79000-G8976-1151
Remove the cover and set it aside temporarily.
Figure 2.4
Removing the Cover
Carefully flip the device over to expose the screws that secure the main inner as-
sembly to the chassis.
2.2.2 Accessing Modules on the Bottom Row
Module Replacement
11