Desire D22
CAUTION: Tighten the C-clamp pipe bolt to about 18 inch lbs.
Installing the Track Fixture
1:
2:
3:
WARNING:
4:
Addressing
Fixture addresses must be set between 1 and 510. Each Desire fixture must be
considered a separate DMX device for the purpose of DMX line-loading
calculations.
No more than 32 DMX devices can be daisy-chained together on a single run.
For runs of fixtures totaling more than 32 DMX devices, a DMX splitter will
need to be used to split the DMX runs.
When using RDM with track fixtures, ETC recommends connecting no more
than 20 fixtures on a single run.

Initial Power Up

Control and configuration of the Desire D22 can be achieved over a
DMX/RDM control network, or directly from a connected computer running
appropriate software. When controlling the D22 directly from a PC, a
Gadget II Interface or DMX/RDM gateway is required.
Desire D22
(Approximately finger tight plus up to one-quarter
turn.) Do not use excessive force.
Insert the DataTrack adapter into
the track. The adapter only fits
into the track one way with the
tabs nesting into the track's
groove.
Rotate the locking mechanisms to
lock the adapter into place.
Use the circuit selection lock to
select circuit 1 or 2. The desired
circuit number should point
toward the center of the adaptor.
When using the circuit selection lock, ensure the
selected circuit is a constant power circuit. Dialing into
a dimmable circuit may cause fixture damage that will
void the ETC warranty.
Focus the fixture.