Power; Electrical; Input And Power Factor; Fixtures Per Circuit - ETC Halcyon Gold User Manual

Table of Contents

Advertisement

Power

WARNING:
to avoid damage to the fixture's internal power supply and other electrical
components. Using a dimmable power source can damage the fixture and
will void the warranty.

Electrical

• 100–240 VAC at 50/60 Hz
• Maximum power consumption: 684 W

Input and Power Factor

The values listed below were measured with LEDs at full and all motors functioning.
VAC
Amps
100
6.9
120
5.7
200
3.4
208
3.3
220
3.1
230
3.0
240
2.9

Fixtures per Circuit

Up to two fixtures are allowed per circuit via an ETC R20 or similar breaker module. Consult
the upstream breaker trip curves when using other equipment.

Connector Specifications

WARNING:
plug with integral cord grip that is within the voltage and amperage rating
of this luminaire.
AVERTISSEMENT :
une prise de mise à la terre avec décharge de traction intégrée qui respecte
la tension et l'ampérage de ce luminaire.
A power input cable with powerCON
input cable is rated for maximum 20 A/120 VAC and 16 A/240 VAC. Install a suitable
connector to meet the installation requirements. See the following wire color code chart:
Wire Color Code (EU) Wire Color Code (US Standard) Connection type Terminal
Green/Yellow
Blue
Brown
9
Connect the fixture to a non-dimmable power source in order
Hz
Watts
VA
50
684
60
674
50
649
60
646
50
646
50
646
60
644
Risk of Shock and Fire. Assemble a grounding-type attachment
Risque de choc et d'incendie. Assurez-vous d'utiliser
®
TRUE1
Green
White
Black
PF
691
0.99
676
0.98
676
0.95
608
0.94
674
0.95
676
0.94
697
0.91
®
TOP input to bare ends is provided. The power
Earth/Ground
Neutral
Line (Live)
N
L
Halcyon Gold User Manual