ETC Installation Guide
Desire D22
Installing the Canopy Mount Fixture
The Canopy Mount fixture is installed on to a RACO 232 series 4 x 2-1/8 inch
deep double junction box. The fixture is supplied with a divider to separate
the data network from the line voltage inside the junction box.
CAUTION: Separate the line voltage from the data side in the
DMX/RDM Cable Installation
1:
Terminate DMX/RDM input from the
control source to the junction box.
If using Belden 9729:
a: See the
b: Install the screw terminal
Desire D22
Installation hook
Canopy
junction box. Install the voltage barrier provided by ETC.
DMX Cable Preparation
for Screw Termination Setup
Guide
for instructions to prepare
and terminate Belden 9729 for
DMX input cable to the screw
terminal connector.
connector with wires terminated
to the DMX/RDM Input receptacle
on the termination board.
Data/Voltage
divider
Mounting plate
assembly
Belden 9729 (or equivalent) wire
termination to screw connector
Page 5 of 8
Junction box
(not provided)
From a DMX/RDM source
4 to 8 = n/c
ETC