SECTION 3
NOTE
When performing a fluid change or topping
off the fill, the proper level should be at half
of the sight glass, with the machine off.
Mixing, changing or adding other lubricants
within the compressor unit may void the
air-end warranty.
LUBRICANT
Sullube
A - 8,000 hours or once per year, whichever comes first.
C - When measured pressure loss exceeds 20 psig (1.3 bar).
D - When measured pressure loss exceeds 10 psig (0.7 bar).
E - When required as the result of fluid analysis or known contamination.
G - Every 2,000 hours.
CAUTION
The use of plastic bowls on line filters and
other plastic airline components without
metal guards can be hazardous. Synthetic
coolants or the additives used in mineral
oils can alter their structural integrity and
create hazardous conditions. Metal bowls
should be used on any pressurized system
for safety concerns.
"The Plastic Pipe Institute recommends
against the use of thermoplastic pipe to
transport compressed air or other com-
pressed gases in exposed above ground
locations, e.g in exposed plant piping." (I)
Sullube should no be used with PVC piping
systems. It may affect the bond at
cemented joints. Certain other plastic mate-
rials may also be affected.
(I) Plastic Pipe Institute, Recommendation
B, Adopted January 19, 1972.
3.7
Sulliar encourages its customers to participate in a
fluid analysis program with the fluid suppliers. In
some cases the analysis results suggest a fluid
change interval which differs from the User Manual.
Contact a Sulliar representative for details.
3.8
FLUID CHANGE
FLUID FILTER CHANGE
A,E
TS20C USER MANUAL

APPLICATION GUIDE

LUBRICATION CHANGE
RECOMMENDATIONS AND
MAINTENANCE, FLUID
FILTER AND SEPARATOR
SEPARATOR CHANGE
G,C
A,D