DB31, ...
DBX94.1
Heatsink temperature pre-warning
Edge evaluation: no
Signal state 1 or
The drive module sends the warning "heatsink temperature pre-warning" to the PLC.
edge change
This triggers the following:
0 → 1
Signal state 0 or
The drive module heatsink temperature pre-warning has not responded.
edge change
1 → 0
Application
As soon as "heatsink temperature warning" has been signaled, the PLC can, for example, initiate
example(s)
controlled shutdown of the drives.
Additional references /DA/ Diagnostics Guide
DB31, ...
DBX94.2
Ramp-up completed
Edge evaluation: no
Signal state 1 or
The PLC is signaled, that after a new speed setpoint has entered, the speed actual value has
edge change
reached the speed tolerance bandwidth:
0 → 1
MD1426 $MD_SPEED_DES_EQ_ACT_TOL (tolerance bandwidth for n
and has remained within this tolerance bandwidth for at least the time defined using machine data:
MD1427 $MD_SPEED_DES_EQ_ACT_DELAY (delay time n
refer to the diagram).
Even if the speed actual value leaves the tolerance band (because of speed fluctuations resulting
from changes in load) the "ramp-up completed" signal remains (1 signal).
Signal state 0 or
The conditions described above have not yet been fulfilled. The ramp-up has therefore not yet been
edge change
completed.
1 → 0
NC/PLC Interface Signals (Z1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Signal(s) updated: cyclic
Terminal 5 on the infeed/regenerative feedback module is simultaneously activated.
The drive module is switched off after 20 seconds. The drives are stopped when the impulse
enable is removed. Then alarm 300515 is triggered.
Signal(s) updated: cyclic