DB10
DBX108.7
NC Ready
Edge evaluation: no
Signal state 1 or
The control system is ready.
edge change 0 → 1
This interface signal is an image of the relay contact "NC Ready".
This signal is set if:
Signal state 0 or
The control is not ready. The relay contact "NC Ready" is open.
edge change 1 → 0
The following faults will cause NC Ready to be canceled:
If the signal "NC Ready" goes to 0 the following measures are introduced by the control if they are
still possible:
For further information see References!
The control is not ready again until after POWER ON.
Corresponding to ....
Relay contact "NC Ready"
References
/DA/ Diagnostics Guide
/FB1/ Description of Functions Basic Machine; PLC Basic Program (P3)
DB10
DBX109.0
NCK alarm is active
Edge evaluation: no
Signal state 1 or
At least one NCK alarm is present.
edge change 0 → 1
This is a group signal for the interface signals
DB21, ... DBX36.6 (channel-specific NCK alarm is active)
of all existing channels.
Signal state 0 or
No NCK alarm is active.
edge change 1 → 0
Corresponding to ....
DB21, ... DBX36.6 (channel-specific NCK alarm present)
DB21, ... DBX36.6 (NCK alarm with processing stop present)
References
/DA/ Diagnostics Guide
NC/PLC Interface Signals (Z1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Signal(s) updated: cyclic
Relay contact "NC Ready" is closed
All the voltages in the control have been established
The control is in the cyclic mode
Undervoltage and overvoltage monitoring function has responded
Individual components are not ready (NCK CPU Ready)
NC CPU watchdog
The controller enable signals are withdrawn (this stops the drives)
The following measures are introduced by the PLC basic program:
Status signals from NCK to PLC (user interface) are deleted (cleared)